SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wood Matthew D)
 

Sökning: WFRF:(Wood Matthew D) > The effect of a mid...

The effect of a midfoot cut in the outer sole of a shoe on intrinsic foot kinematics during walking.

Arndt, Anton, 1968- (författare)
Gymnastik- och idrottshögskolan,Laboratoriet för biomekanik och motorisk kontroll (BMC)
Lundgren, Paul (författare)
Liu, Anmin (författare)
visa fler...
Nester, Christopher (författare)
Maiwald, Christian (författare)
Jones, Richard (författare)
Lundberg, Arne (författare)
visa färre...
 (creator_code:org_t)
Informa UK Limited, 2013
2013
Engelska.
Ingår i: Footwear Science. - : Informa UK Limited. - 1942-4280 .- 1942-4299. ; 5:1, s. 63-69
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Modifications in shoe outer soles are frequently made with the intention of altering biomechanics of the foot inside the shoe. These modifications are however, generally based upon intuition with little or no scientific data for support. The purpose of this study was to quantify changes in intrinsic foot segmental kinematics between walking in a neutral shoe and a shoe modified with a clear cut forming a break underneath the midfoot, approximating the Lisfrancs joint.Five healthy male subjects participated in the study. Intracortical pins were inserted under sterile conditions and local anaesthetic in nine different bones of the foot and shank. The subjects performed 10 walking trials in both a neutral, standard, flatsoled, flexible walking shoe and in the same shoe with an approximately 1 cm deep cut aligned with the subjects’ Lisfrancs joint. Material tests showed that the cut reduced midfoot shoe bending stiffness by 23% to 38% and torsional stiffness by 23% to 28%. A helical axis approach was applied for calculating the 3D rotations about relevant joints.Kinematic trajectories in the sagittal, frontal, and transverse planes were normalised to the stance phase for seven selected joints to compare rotation patterns when wearing the two shoe conditions. Although one out of 21 ranges of motion (ROM) showed a significant difference, there is strong reason to regard this as the result of a type 1 error. Apart from this no differences in ROM occurred between the shoe conditions.The low subject number reduced the statistical power of the results. However, the study indicated that outer sole modifications that may be assumed to have clear effects upon foot kinematics, do not necessarily do so.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Annan medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Other Medical Biotechnology (hsv//eng)

Nyckelord

Medicin/Teknik
Medicine/Technology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy