Underestimation of intraocular pressure after photorefractive keratectomy : a biomechanical analysis

Hallberg, Per (författare)
Department of Biomedical Engineering and Informatics, University Hospital, Umeå, Sweden
Eklund, Anders (författare)
Department of Biomedical Engineering and Informatics, University Hospital, Umeå, Sweden
Santala, Kenneth (författare)
Umeå universitet,Oftalmiatrik,Umeå University, Department of Clinical Science, Ophthalmology
visa fler...
Koskela, Timo (författare)
Koskela Eye Clinic, Umeå
Lindahl, Olof A. (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik
Lindén, Christina (författare)
Umeå universitet,Oftalmiatrik,Umeå University, Department of Clinical Science, Ophthalmology
visa färre...
 (creator_code:org_t)
2006-07-26
2006
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - : Springer. - 0140-0118 .- 1741-0444. ; 44, s. 609-618
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Excimer laser surgery, to correct corneal refraction, induces changes in corneal thickness and curvature. Both factors can cause measurement errors when determining intraocular pressure (IOP). This study evaluates effects of photorefractive keratectomy (PRK) on IOP measurements, using Goldmann applanation tonometry (GAT) and Applanation resonance tonometry (ART), in an in vitro model. Six porcine eyes was enucleated and pressurised to a constant IOP = 30 mmHg. After removal of the epithelium, the eyes were PRK-treated for a total of 25 dioptres. The measured IOP decreased 13.2 mmHg for GAT and 9.0 mmHg for ART. The total underestimation by GAT was larger than for ART, and a part of the ART underestimation (3.5 mmHg) was assigned to sensitivity to the change in corneal surface structure resulting from the removal of epithelium. The flat contact probe of GAT, as compared with the convex tip of ART, provided explanation for the difference in IOP measurement error after PRK.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Refractive correction
Laser
Applanation resonance tonometry
Goldmann applanation tonometry
Glaucoma
Measurement error
Eye
oftalmiatrik
ophthalmology
Medical Engineering for Healthcare

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy