Sökning: WFRF:(Ribeiro Tiago) >
The Concept of Dyna...
The Concept of Dynamic Hosting Capacity for Distributed Energy Resources : Analytics and Practical Considerations
-
- de Oliveira, Tiago Elias Castelo (författare)
- Electrical Energy Systems, Technological University of Eindhoven, Eindhoven, The Netherlands
-
- Bollen, Math (författare)
- Luleå tekniska universitet,Energivetenskap,Electric Power Engineering
-
- Ribeiro, Paulo Fernando (författare)
- Advanced Power Technologies and Innovations in Systems and Smart Grids Group, Federal University of Itajuba, Itajuba, Brazil
-
visa fler...
-
- de Carvalho, Pedro M. S. (författare)
- Energy Scientific Area, Instituto Superior Tecnico, Lisbon, Portugal
-
- Zambroni, Antônio C. (författare)
- Advanced Power Technologies and Innovations in Systems and Smart Grids Group, Federal University of Itajuba, Itajuba, Brazil
-
- Bonatto, Benedito D. (författare)
- Advanced Power Technologies and Innovations in Systems and Smart Grids Group, Federal University of Itajuba, Itajuba, Brazil
-
visa färre...
-
(creator_code:org_t)
- 2019-07-04
- 2019
- Engelska.
-
Ingår i: Energies. - : MDPI. - 1996-1073. ; 12:13
- Relaterad länk:
-
https://doi.org/10.3...
-
visa fler...
-
https://www.mdpi.com...
-
https://urn.kb.se/re...
-
https://doi.org/10.3...
-
visa färre...
Abstract
Ämnesord
Stäng
- The hosting capacity approach is presented as a planning, improving, and communication tool for electrical distribution systems operating under specific uncertainties, such as power quality issues, power stabilities, and reliability, among others. In other words, it is an important technique, when renewable sources are present, to answer the amount of power that is possible to supply to the system without trespassing power performance limits. However, the power flow in a distribution system, for instance, can change throughout time due to the penetration of distributed generation, as well as load consumption. Based on the dynamic nature existing in distribution grids nowadays, it is important to highlight that the hosting capacity should not be calculated in a specifically chosen time only, but must be analyzed throughout a period of time. Thus, this paper introduces an extended concept of hosting capacity in relation to an integrated impact of harmonic voltage distortion and voltage rise as a function of time for daily, weekly, monthly, or even yearly periods. This extended concept is named as Dynamic Hosting Capacity (DHC(t)). General aspects of DHC(t) are demonstrated via measured data on a photovoltaic system (PV) connected at a low-voltage (LV) side of a university building.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
Nyckelord
- distributed generation
- distributed energy resources
- dynamic hosting capacity
- power quality indexes
- voltage rise
- harmonic voltage distortion
- Electric Power Engineering
- Elkraftteknik
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
-
Energies
(Sök värdpublikationen i LIBRIS)
Till lärosätets databas