Sökning: WFRF:(Yu Zhaohua) > (2015-2019) > Near infrared radia...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02745naa a2200397 4500 | |
001 | oai:DiVA.org:uu-257175 | |
003 | SwePub | |
008 | 150630s2015 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-2571752 URI |
024 | 7 | a https://doi.org/10.1117/12.20866612 DOI |
040 | a (SwePub)uu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a kon2 swepub-publicationtype |
100 | 1 | a Söderberg, Per G.u Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)perso438 |
245 | 1 0 | a Near infrared radiation damage mechanism in the lens |
264 | 1 | b SPIE,c 2015 |
338 | a print2 rdacarrier | |
520 | a The current data strongly indicates that there is no photochemical effect of in vivo exposure to 1090 nm near IRR radiation within the pupil. Four groups of 20 Sprague-Dawley rats were unilaterally exposed in vivo to 96 W.cm(-2) centered inside the pupil for 10, 18, 33 and 60 min, respectively depending on group belonging. This resulted in radiant exposure doses of 57, 103, 198 and 344 kJ.cm(-2). Temperature evolution at the limbus during the exposure and difference of intensity of forward light scattering between the exposed and the contralateral not exposed eye was measured at 1 week after exposure. The temperature at the limbus was found to increase exponentially towards an asymptote with an asymptote temperature of around 7 degrees C and a time constant (1/k) of around 15 s. No increase of light scattering was found despite that the cumulated radiant exposure dose was [80; 250] times the threshold for photochemically induced cataract suggested by previous empirical data. It is concluded that at 1090 nm near IRR there is no photochemical effect. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oftalmologi0 (SwePub)302172 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Ophthalmology0 (SwePub)302172 hsv//eng |
653 | a near infrared radiation | |
653 | a cataract | |
653 | a in vivo | |
653 | a photochemical | |
653 | a thermal | |
700 | 1 | a Talebizadeh, Nooshinu Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)noota977 |
700 | 1 | a Galichanin, Konstantinu Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)konga695 |
700 | 1 | a Kronschläger, Martinu Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)markr689 |
700 | 1 | a Schulmeister, Karl4 aut |
700 | 1 | a Yu, Zhaohuau Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)zhayu760 |
710 | 2 | a Uppsala universitetb Oftalmiatrik4 org |
773 | 0 | t OPHTHALMIC TECHNOLOGIES XXVd : SPIEz 9781628413977 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-257175 |
856 | 4 8 | u https://doi.org/10.1117/12.2086661 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy