SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Yu Zhaohua)
 

Sökning: WFRF:(Yu Zhaohua) > AI-based detection ...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003447nam a2200361 4500
001oai:DiVA.org:uu-502040
003SwePub
008230519| | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-5020402 URI
040 a (SwePub)uu
041 a engb eng
042 9 SwePub
072 7a vet2 swepub-contenttype
072 7a ovr2 swepub-publicationtype
100a Kisonaite, Konstancijau Uppsala universitet,Oftalmiatrik,Per Söderberg4 aut0 (Swepub:uu)konki863
2451 0a AI-based detection of the inner limit of the minimal waist of the nerve fiber bundles in the ONH in subjects with peripapillary atrophy
338 a print2 rdacarrier
520 a Purpose: To verify that a deep learning model developed by our research group does not wrongly identify the outer edge of the atrophic zone in eyes with peripapillary atrophy (PPA) rather than a point adjacent to the external limit of the minimal waist of the nerve fiber bundles in the ONH.Methods: Subjects with at least one eye with PPA were included. The ONH of the eye with PPA was imaged with colour photography, and the three-dimensional structure of the ONH was captured three times at one occasion with SS-OCT (Topcon Triton, Japan). Each capture was exported to a custom-made software for analysis. The custom-made software, AutoPimd, allowed fully automatic localization of the external limit of the minimal waist of the nerve fiber layer in space using deep learning-model. An en face visualization of the frontal plane of the ONH and user measurement in the en face view is possible. The en face view in the OCT volume was verified to render PPA as imaged in the photograph. The distance between the ONH center and the extreme edge of the PPA was measured in the en face view of the OCT. Then, the frontal plane distance between the ONH center and the fully automatically detected external limit of the minimal waist of the nerve fiber layer in the ONH was measured along the same frontal plane angle.Results: A 95 % confidence interval for the mean difference between the distance from center of the ONH to the extreme edge of the PPA, and the distance from the center of the ONH to the corresponding fully automatically detected outer limit of the minimal waist of the nerve fiber layer was estimated to 692 ± 192 μm (d.f = 5).Conclusion: Our AI model does not wrongly localize the outer limit of PPA as the external limit of the minimal waist of the nerve fiber layer. The structural representation of the external limit of the minimal waist of the nerve fiber bundles localized by our fully automatic AI model in eyes with PPA remains to be identified.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oftalmologi0 (SwePub)302172 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Ophthalmology0 (SwePub)302172 hsv//eng
653 a ONH
653 a nerve fibers
653 a minimal waist
653 a OCT
653 a artificial intelligence
653 a deep learning
653 a peripapillary atrophy
653 a Ophtalmology
653 a Oftalmiatrik
700a Yu, Zhaohua,d 1983-u Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)zhayu760
700a Söderberg, Per,d 1956-u Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)perso438
710a Uppsala universitetb Oftalmiatrik4 org
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-502040

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kisonaite, Konst ...
Yu, Zhaohua, 198 ...
Söderberg, Per, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy