SwePub
Sök i LIBRIS databas

  Utökad sökning

hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Naturresursteknik)
 

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Naturresursteknik) > (2000-2009) > Hydraulic performan...

Hydraulic performance of a full-scale peat and ash biofilter in treatment of industrial landfill leachate

Kängsepp, Pille (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Mathiasson, Lennart (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Dahlblom, Peter, 1947- (författare)
Högskolan Kristianstad,Sektionen för lärande och miljö
visa fler...
Hogland, William (författare)
Mittuniversitetet,Institutionen för teknik och hållbar utveckling (-2013)
visa färre...
 (creator_code:org_t)
SAGE Publications, 2009
2009
Engelska.
Ingår i: Waste Management & Research. - : SAGE Publications. - 0734-242X .- 1096-3669. ; 27:5, s. 512-519
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this study was to evaluate the hydraulic performance of a full-scale on-site vertical-flow biofilter, consisting of a mixture of peat and carbon-containing ash, and a 500 m3 equalization pond prior to the filter-system. The treatment plant was constructed to clean up leachate from an industrial mono-landfill that contained shredder residues of end-of-life vehicles and white goods. With the limited storage capacity of the equalization pond, peak loading rates exceeded up to five to six times the designed daily hydraulic load limit of the biofilter system. Such relatively short overloading events did not negatively affect the purification efficiency. To provide the designed annual irrigation rate on the biofilter of 97 m3 day— 1 (or 133 mm day—1), with large seasonal variations in precipitation, a relatively large pond would be needed. Calculations showed that a storage volume of about 23 000 m3 would be sufficient for annual leachate volumes up to about 35 000 m3. A combination of sprinkler and drip irrigation with straw insulation of the latter made it possible to run the plant continuously even when the ambient air temperature was below zero for more than a month at a time. The grain size distribution of the biofilter medium was noticeably changed after 4 years of usage due to the loading of suspended solids from the leachate and decomposition of the peat, causing reduced hydraulic conductivity.

Ämnesord

ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Other Environmental Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Annan naturresursteknik (hsv//swe)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering (hsv//eng)
NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

On-site leachate treatment
retention pond
equalization pond
hydraulic load
vertical-flow biofilter
wmr 1404-9
NATURAL SCIENCES
NATURVETENSKAP
On-site leachate treatment • retention pond • equalization pond • hydraulic load • vertical-flow biofilter • wmr 1404—9
Environmental engineering
Miljöteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy