Sökning: L773:2412 3811 OR L773:2412 3811 > In situ measurement...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03515naa a2200445 4500 | |
001 | oai:DiVA.org:miun-34869 | |
003 | SwePub | |
008 | 181109s2018 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-348692 URI |
024 | 7 | a https://doi.org/10.3390/infrastructures30300202 DOI |
040 | a (SwePub)miun | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Danielski, Itai,d 1973-u Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande,The Ekoteknik research group4 aut0 (Swepub:miun)itadan |
245 | 1 0 | a In situ measurements of thermal properties of building fabrics using thermography under non-steady state heat flow conditions |
264 | c 2018-07-02 | |
264 | 1 | b MDPI,c 2018 |
338 | a electronic2 rdacarrier | |
520 | a This study describes a quantitative method using thermography to measure the thermal properties of building fabrics that are subjected to non-steady state heat flow due to consistently changing meteorological conditions. The method includes two parts. First, the convection heat transfer coefficient is measured by thermography and heat flux meters on a small segment of the examined building fabric with uniform surface temperature. Then, thermal properties of large building fabrics are evaluated by thermography. The two parts are measured simultaneously. The method was tested on 140/160/190 mm thick massive laminated spruce timber walls of a test facility cabin located in Östersund, Sweden. The results varied by only a few percent in comparison to validation measurements performed with heat flux meters and in comparison, to values from the literature. Due to rapid changes in weather conditions the measured values had large disparity, but still a linear regression with low confidence interval was obtained. Obtaining an accurate value of convection heat transfer was important for achieving high measurement accuracy and, therefore, the value of this parameter should be measured. Other important factors to consider are solar radiation, reflected infrared (IR) radiation from nearby objects and the number of thermal images. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Naturresursteknikx Fjärranalysteknik0 (SwePub)207032 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Environmental Engineeringx Remote Sensing0 (SwePub)207032 hsv//eng |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Samhällsbyggnadsteknikx Husbyggnad0 (SwePub)201032 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Civil Engineeringx Building Technologies0 (SwePub)201032 hsv//eng |
653 | a Conductivity | |
653 | a building fabrics | |
653 | a thermal transmittance | |
653 | a thermal imaging | |
653 | a thermography | |
653 | a U-value | |
653 | a heat flux meters | |
700 | 1 | a Fröling, Morgan,d 1966-u Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande4 aut0 (Swepub:miun)morfro |
710 | 2 | a Mittuniversitetetb Avdelningen för ekoteknik och hållbart byggande4 org |
773 | 0 | t Infrastructuresd : MDPIg 3:3q 3:3x 2412-3811 |
856 | 4 | u https://doi.org/10.3390/infrastructures3030020y Fulltext |
856 | 4 | u https://miun.diva-portal.org/smash/get/diva2:1261959/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print |
856 | 4 | u https://www.mdpi.com/2412-3811/3/3/20/pdf |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-34869 |
856 | 4 8 | u https://doi.org/10.3390/infrastructures3030020 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy