Surface-guided tomotherapy improves positioning and reduces treatment time : A retrospective analysis of 16 835 treatment fractions
-
- Haraldsson, André (författare)
- Lund University,Lunds universitet,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Lund University Research Groups,Skåne University Hospital
-
- Ceberg, Sofie (författare)
- Lund University,Lunds universitet,Radiotherapy Physics,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments
-
- Ceberg, Crister (författare)
- Lund University,Lunds universitet,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Lund University Research Groups
-
visa fler...
-
- Bäck, Sven (författare)
- Lund University,Lunds universitet,Radiotherapy Physics,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
- Engelholm, Silke (författare)
- Skåne University Hospital
-
- Engström, Per E. (författare)
- Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- 2020-06-26
- 2020
- Engelska 10 s.
-
Ingår i: Journal of Applied Clinical Medical Physics. - : Wiley. - 1526-9914. ; 21:8, s. 139-148
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://onlinelibrar...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: In this study, we have quantified the setup deviation and time gain when using fast surface scanning for daily setup/positioning with weekly megavoltage computed tomography (MVCT) and compared it to daily MVCT. Methods: A total of 16 835 treatment fractions were analyzed, treated, and positioned using our TomoTherapy HD (Accuray Inc., Madison, USA) installed with a Sentinel optical surface scanning system (C-RAD Positioning AB, Uppsala, Sweden). Patients were positioned using in-room lasers, surface scanning and MVCT for the first three fractions. For the remaining fractions, in-room laser was used for setup followed by daily surface scanning with MVCT once weekly. The three-dimensional (3D) setup correction for surface scanning was evaluated from the registration between MVCT and the planning CT. The setup correction vector for the in-room lasers was assessed from the surface scanning and the MVCT to planning CT registration. The imaging time was evaluated as the time from imaging start to beam-on. Results: We analyzed 894 TomoTherapy treatment plans from 2012 to 2018. Of all the treatment fractions performed with surface scanning, 90 % of the residual errors were within 2.3 mm for CNS (N = 284), 2.9 mm for H&N (N = 254), 8.7 mm for thorax (N = 144) and 10.9 for abdomen (N = 134) patients. The difference in residual error between surface scanning and positioning with in-room lasers was significant (P < 0.005) for all sites. The imaging time was assessed as total imaging time per treatment plan, modality, and treatment site and found that surface scanning significantly reduced patient on-couch time compared to MVCT for all treatment sites (P < 0.005). Conclusions: The results indicate that daily surface scanning with weekly MVCT can be used with the current target margins for H&N, CNS, and thorax, with reduced imaging time.
Ämnesord
- NATURVETENSKAP -- Fysik -- Annan fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Other Physics Topics (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- helical
- radiotherapy
- SGRT
- surface scanning
- tomotherapy