SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Cheng Hsuan)
 

Sökning: WFRF:(Cheng Hsuan) > Energy savings appr...

Energy savings approaches for high-tech manufacturing factories

Hu, Shih-Cheng (författare)
Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 106, Taiwan.
Lin, Tee (författare)
Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 106, Taiwan.
Huang, Shao-Huan (författare)
Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 106, Taiwan.
visa fler...
Fu, Ben-Ran (författare)
Ming Chi Univ Technol, Dept Mech Engn, New Taipei 243, Taiwan.
Hu, Ming-Hsuan (författare)
KTH,Energiteknik
visa färre...
Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 106, Taiwan Ming Chi Univ Technol, Dept Mech Engn, New Taipei 243, Taiwan. (creator_code:org_t)
ELSEVIER, 2020
2020
Engelska.
Ingår i: CASE STUDIES IN THERMAL ENGINEERING. - : ELSEVIER. - 2214-157X. ; 17
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study integrates a fab energy simulation (FES) tool and energy conversion factors to analyze energy consumption and identify energy savings opportunities of high-tech manufacturing factories. The data used is the 169,124 MW h annual energy consumption of a Taiwanese semiconductor manufacturing fab. We proposed a compressed/clean dry air (CDA) system as a two-pressure system using a heated-type dryer. The proposed method achieved 3050 MW h as the highest energy savings in the CDA system compared to the original fab data. The results also indicate that lowering the make-up air unit (MAU) operating temperature caused significant energy savings for the high-temperature water chiller system. When the outlet air temperature of the MAU system was 14 degrees C, the maximum energy savings were 3532 MW h. In addition, the process cooling water (PCW) system could potentially save energy by reducing the pumping head of water in its open system. Therefore, we suggested a closed PCW system that reached a maximum energy saving of 1541 MW h.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Nyckelord

Fab energy simulation
Energy conversion factors
Energy consumption
Energy savings
Semiconductor manufacturing

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hu, Shih-Cheng
Lin, Tee
Huang, Shao-Huan
Fu, Ben-Ran
Hu, Ming-Hsuan
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
Artiklar i publikationen
CASE STUDIES IN ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy