SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Gäbel Jakob 1971)
 

Search: WFRF:(Gäbel Jakob 1971) > A single-centre exp...

A single-centre experience of over one thousand lead extractions.

Kennergren, Charles, 1948 (author)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Bjurman, Christian, 1983 (author)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research
Wiklund, Roger (author)
show more...
Gäbel, Jakob, 1971 (author)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
show less...
 (creator_code:org_t)
2009-03-27
2009
English.
In: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - : Oxford University Press (OUP). - 1532-2092. ; 11:5, s. 612-7
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • AIMS: The aim of the study was to present a single-centre experience of pacemaker and implantable cardioverter defibrillator (ICD) lead extraction using different methods, mainly laser-assisted extraction. METHODS AND RESULTS: Data from 1032 leads and 647 procedures were gathered. A step-by-step approach using different techniques while performing an ongoing risk-benefit analysis was used. The most common indications were local infection, systemic infection, non-functional lead, elective lead replacement, and J-wire fracture. Mean implantation time for all leads was 69 months and for laser-extracted leads 91 months. Laser technique was used to extract 60% of the leads, 29% were manually extracted, 6% extracted with mechanical tools, 4% were surgically removed, and 0.6% extracted by a femoral approach. Failure rate was 0.7%, and major complication rate was 0.9%. No extraction-related mortality occurred. Median time for laser extraction was 2 min. Long implantation time was not a risk factor for failure or for complication. CONCLUSION: Pacing and ICD leads can safely, successfully, and effectively be extracted. Leads can often be extracted by a superior transvenous approach; however, open-chest and femoral extractions are still required. Laser-assisted lead extraction proved to be a useful technique to extract leads that could not be removed by manual traction. The results indicate that the paradigm of abandoning redundant leads, instead of removing them, may have to be reconsidered.

Keyword

Adolescent
Adult
Aged
Aged
80 and over
Child
Defibrillators
Implantable
Device Removal
adverse effects
methods
Endpoint Determination
Equipment Failure
Female
Foreign-Body Migration
Humans
Infection Control
Male
Middle Aged
Pacemaker
Artificial
Retrospective Studies
Risk Assessment
Young Adult

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view