SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sarajlic M.)
 

Sökning: WFRF:(Sarajlic M.) > Germanium "hexa" de...

Germanium "hexa" detector : Production and testing

Sarajlić, M. (författare)
Deutsches Elektronen-Synchrotron (DESY), Germany
Pennicard, D. (författare)
Deutsches Elektronen-Synchrotron (DESY), Germany
Smoljanin, S. (författare)
Deutsches Elektronen-Synchrotron (DESY), Germany
visa fler...
Hirsemann, H. (författare)
Deutsches Elektronen-Synchrotron (DESY), Germany
Struth, B. (författare)
Deutsches Elektronen-Synchrotron (DESY), Germany
Fritzsch, T. (författare)
Fraunhofer Institute for Reliability and Microintegration, Germany
Rothermund, M. (författare)
Fraunhofer Institute for Reliability and Microintegration, Germany
Zuvic, M. (författare)
Mirion Technologies (Canberra), France
Lampert, M. O. (författare)
Mirion Technologies (Canberra), France
Askar, M. (författare)
Al-Farabi Kazakh National University, Kazakhstan
Graafsma, Heinz (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion,Deutsches Elektronen-Synchrotron (DESY), Germany
visa färre...
 (creator_code:org_t)
2017
2017
Engelska.
Ingår i: Journal of Instrumentation. - 1748-0221. ; 12:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Here we present new result on the testing of a Germanium sensor for X-ray radiation. The system is made of 3 × 2 Medipix3RX chips, bump-bonded to a monolithic sensor, and is called "hexa". Its dimensions are 45 × 30 mm2 and the sensor thickness was 1.5 mm. The total number of the pixels is 393216 in the matrix 768 × 512 with pixel pitch 55 μ m. Medipix3RX read-out chip provides photon counting read-out with single photon sensitivity. The sensor is cooled to -126°C and noise levels together with flat field response are measured. For -200 V polarization bias, leakage current was 4.4 mA (3.2 μ A/mm2). Due to higher leakage around 2.5% of all pixels stay non-responsive. More than 99% of all pixels are bump bonded correctly. In this paper we present the experimental set-up, threshold equalization procedure, image acquisition and the technique for bump bond quality estimate.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Nyckelord

Hybrid detectors
Materials for solid-state detectors
Solid state detectors
X-ray detectors

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy