Sökning: WFRF:(Szász Robert Zoltán) >
Evaluation of sub g...
Evaluation of sub grid scale and local wall models in Large-eddy simulations of separated flow
-
- Al Sam, Ali (författare)
- Lund University,Lunds universitet,Strömningsteknik,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Fluid Mechanics,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Szász, Robert-Zoltán (författare)
- Lund University,Lunds universitet,Strömningsteknik,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Fluid Mechanics,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Revstedt, Johan (författare)
- Lund University,Lunds universitet,Strömningsteknik,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Fluid Mechanics,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
J. Churchfield, Matthew (redaktör/utgivare)
-
visa färre...
-
(creator_code:org_t)
- 2015-10-16
- 2015
- Engelska 11 s.
-
Ingår i: 2nd Symposium on OpenFOAM® in Wind Energy. - : EDP Sciences. ; 5
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://www.e3s-conf...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The performance of the Sub Grid Scale models is studied by simulating a separated flow over a wavy channel. The first and second order statistical moments of the resolved velocities obtained by using Large-Eddy simulations at different mesh resolutions are compared with Direct Numerical Simulations data. The effectiveness of modeling the wall stresses by using local log-law is then tested on a relatively coarse grid. The results exhibit a good agreement between highly-resolved Large Eddy Simulations and Direct Numerical Simulations data regardless the Sub Grid Scale models. However, the agreement is less satisfactory with relatively coarse grid without using any wall models and the differences between Sub Grid Scale models are distinguishable. Using local wall model returned the basic flow topology and reduced significantly the differences between the coarse meshed Large-Eddy Simulations and Direct Numerical Simulations data. The results show that the ability of local wall model to predict the separation zone depends strongly on its implementation way.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas