Sökning: WFRF:(Zsigmond Peter) >
High-Resolution Las...
High-Resolution Laser Doppler Measurements of Microcirculation in the Deep Brain Structures : A Method for Potential Vessel Tracking.
-
- Wårdell, Karin (författare)
- Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,MINT
-
- Hemm-Ode, Simone (författare)
- Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten,University of Applied Sciences and Arts Northwestern Switzerland, Muttenz , Switzerland,MINT
-
- Rejmstad, Peter (författare)
- Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten,MINT
-
visa fler...
-
- Zsigmond, Peter (författare)
- Linköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Neurokirurgiska kliniken US
-
visa färre...
-
(creator_code:org_t)
- 2016-01-22
- 2016
- Engelska.
-
Ingår i: Stereotactic and Functional Neurosurgery. - : S. Karger. - 1011-6125 .- 1423-0372. ; 94:1, s. 1-9
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
http://liu.diva-port...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND: Laser Doppler flowmetry (LDF) can be used to measure cerebral microcirculation in relation to stereotactic deep brain stimulation (DBS) implantations.OBJECTIVE: To investigate the microcirculation and total light intensity (TLI) corresponding to tissue grayness in DBS target regions with high-resolution LDF recordings, and to define a resolution which enables detection of small vessels.METHODS: Stereotactic LDF measurements were made prior to DBS implantation with 0.5-mm steps in the vicinity to 4 deep brain targets (STN, GPi, Vim, Zi) along 20 trajectories. The Mann-Whitney U test was used to compare the microcirculation and TLI between targets, and the measurement resolution (0.5 vs. 1 mm). The numbers of high blood flow spots along the trajectories were calculated.RESULTS: There was a significant difference (p < 0.05) in microcirculation between the targets. High blood flow spots were present at 15 out of 510 positions, 7 along Vim and GPi trajectories, respectively. There was no statistical difference between resolutions even though both local blood flow and TLI peaks could appear at 0.5-mm steps.CONCLUSIONS: LDF can be used for online tracking of critical regions presenting blood flow and TLI peaks, possibly relating to vessel structures and thin laminas along stereotactic trajectories.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Neurologi (hsv//swe)