High-Resolution Laser Doppler Measurements of Microcirculation in the Deep Brain Structures : A Method for Potential Vessel Tracking.

Wårdell, Karin (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,MINT
Hemm-Ode, Simone (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten,University of Applied Sciences and Arts Northwestern Switzerland, Muttenz , Switzerland,MINT
Rejmstad, Peter (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten,MINT
visa fler...
Zsigmond, Peter (författare)
Linköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Neurokirurgiska kliniken US
visa färre...
 (creator_code:org_t)
2016-01-22
2016
Engelska.
Ingår i: Stereotactic and Functional Neurosurgery. - : S. Karger. - 1011-6125 .- 1423-0372. ; 94:1, s. 1-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Laser Doppler flowmetry (LDF) can be used to measure cerebral microcirculation in relation to stereotactic deep brain stimulation (DBS) implantations.OBJECTIVE: To investigate the microcirculation and total light intensity (TLI) corresponding to tissue grayness in DBS target regions with high-resolution LDF recordings, and to define a resolution which enables detection of small vessels.METHODS: Stereotactic LDF measurements were made prior to DBS implantation with 0.5-mm steps in the vicinity to 4 deep brain targets (STN, GPi, Vim, Zi) along 20 trajectories. The Mann-Whitney U test was used to compare the microcirculation and TLI between targets, and the measurement resolution (0.5 vs. 1 mm). The numbers of high blood flow spots along the trajectories were calculated.RESULTS: There was a significant difference (p < 0.05) in microcirculation between the targets. High blood flow spots were present at 15 out of 510 positions, 7 along Vim and GPi trajectories, respectively. There was no statistical difference between resolutions even though both local blood flow and TLI peaks could appear at 0.5-mm steps.CONCLUSIONS: LDF can be used for online tracking of critical regions presenting blood flow and TLI peaks, possibly relating to vessel structures and thin laminas along stereotactic trajectories.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Nyckelord

Deep brain stimulation · Laser Doppler flowmetry ·Stereotactic neurosurgery · Microcirculation · Navigation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wårdell, Karin
Hemm-Ode, Simone
Rejmstad, Peter
Zsigmond, Peter
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinsk biotek ...
och Biomedicinsk lab ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Neurologi
Artiklar i publikationen
Stereotactic and ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy