SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lewander Märta)
 

Sökning: WFRF:(Lewander Märta) > Development of a 3-...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004537naa a2200445 4500
001oai:lup.lub.lu.se:515a92da-4117-43f4-9bf6-9ce5b0f53c1c
003SwePub
008180328s2018 | |||||||||||000 ||eng|
024a https://lup.lub.lu.se/record/515a92da-4117-43f4-9bf6-9ce5b0f53c1c2 URI
024a https://doi.org/10.1002/jbio.2017000972 DOI
040 a (SwePub)lu
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Larsson, Jimu Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)forb-jla
2451 0a Development of a 3-dimensional tissue lung phantom of a preterm infant for optical measurements of oxygen—Laser-detector position considerations
264 c 2017-09-14
264 1b Wiley,c 2018
520 a There is a need to further improve the clinical care of our most vulnerable patients—preterm infants. Novel diagnostic and treatment tools facilitate such advances. Here, we evaluate a potential percutaneous optical monitoring tool to assess the oxygen and water vapor content in the lungs of preterm babies. The aim is to prepare for further clinical studies by gaining a detailed understanding of how the measured light intensity and gas absorption signal behave for different possible geometries of light delivery and receiver. Such an experimental evaluation is conducted for the first time utilizing a specially developed 3-dimensional-printed optical phantom based on a geometry model obtained from computer tomography images of the thorax (chest) of a 1700-g premature infant. The measurements yield reliable signals for source–detector distances up to about 50 mm, with stronger gas absorption signals at long separations and positions related to the lower part of the lung, consistent with a larger relative volume of this. The limitations of this study include the omission of scattering tissue within the lungs and that similar optical properties are used for the wavelengths employed for the 2 gases, yielding no indication on the optimal wavelength pair to use.
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk laboratorie- och mätteknik0 (SwePub)206012 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Laboratory and Measurements Technologies0 (SwePub)206012 hsv//eng
650 7a NATURVETENSKAPx Fysikx Atom- och molekylfysik och optik0 (SwePub)103022 hsv//swe
650 7a NATURAL SCIENCESx Physical Sciencesx Atom and Molecular Physics and Optics0 (SwePub)103022 hsv//eng
653 a premature infants
653 a respiratory distress syndrome
653 a tissue phantom
653 a tunable diode laser absorption spectroscopy
700a Liao, Peilangu Lund University,Gasporox AB4 aut
700a Lundin, Patriku Gasporox AB4 aut0 (Swepub:lu)fysi-pld
700a Krite Svanberg, Emilieu Lund University,Lunds universitet,Lunds lasercentrum, LLC,Annan verksamhet, LTH,Lunds Tekniska Högskola,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Lund Laser Centre, LLC,Other operations, LTH,Faculty of Engineering, LTH,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine4 aut0 (Swepub:lu)med-ekv
700a Swartling, Johannesu Gasporox AB4 aut0 (Swepub:lu)fysi-jsw
700a Lewander Xu, Märtau Gasporox AB4 aut
700a Bood, Joakimu Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)forb-jbo
700a Andersson-Engels, Stefanu Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,University College Cork,Tyndall National Institute4 aut0 (Swepub:lu)fysi-san
710a Förbränningsfysikb Fysiska institutionen4 org
773t Journal of Biophotonicsd : Wileyg 11:3q 11:3x 1864-063X
856u http://dx.doi.org/10.1002/jbio.201700097y FULLTEXT
8564 8u https://lup.lub.lu.se/record/515a92da-4117-43f4-9bf6-9ce5b0f53c1c
8564 8u https://doi.org/10.1002/jbio.201700097

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy