SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lind Bengt K)
 

Sökning: WFRF:(Lind Bengt K) > Improved dose respo...

Improved dose response modeling for normal tissue damage and therapy optimization

Adamus-Górka, Magdalena, 1977- (författare)
Stockholms universitet,Medicinsk strålningsfysik (tills m KI)
Lind, Bengt K., Docent (preses)
Stockholms universitet,Medicinsk strålningsfysik (tills m KI)
Brahme, Anders, Professor (preses)
Stockholms universitet,Medicinsk strålningsfysik (tills m KI)
visa fler...
Mavroidis, Panayiotis (preses)
Ten Haken, Randall K., Professor (opponent)
University of Michigan, Ann Arbor
visa färre...
 (creator_code:org_t)
ISBN 9789171555847
Stockholm : Medicinsk strålningsfysik (tills m KI), 2008
Engelska 52 s.
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • The present thesis is focused on the development and application of dose response models for radiation therapy. Radiobiological models of tissue response to radiation are an integral part of the radiotherapeutic process and a powerful tool to optimize tumor control and minimize damage to healthy tissues for use in clinical trials. Ideally, the models could work as a historical control arm of a clinical trial eliminating the need to randomize patents to suboptimal therapies. In the thesis overview part, some of the basic properties of the dose response relation are reviewed and the most common radiobiological dose-response models are compared with regard to their ability to describe experimental dose response data for rat spinal cord using the maximum likelihood method. For vascular damage the relative seriality model was clearly superior to the other models, whereas for white matter necrosis all models were quite good except possibly the inverse tumor and critical element models. The radiation sensitivity, seriality and steepness of the dose-response relation of the spinal cord is found to vary considerably along its length. The cervical region is more radiation sensitive, more parallel, expressing much steeper dose-response relation and more volume dependent probability of inducing radiation myelitis than the thoracic part. The higher number of functional subunits (FSUs) consistent with a higher amount of white matter close to the brain may be responsible for these phenomena. With strongly heterogeneous dose delivery and due to the random location of FSUs, the effective size of the FSU and the mean dose deposited in it are of key importance and the radiation sensitivity distribution of the FSU may be an even better descriptor for the response of the organ. An individual optimization of a radiation treatment has the potential to increase the therapeutic window and improve cure for a subgroup of patients.

Nyckelord

Normal tissue complications
radiobiological models
dose-response
volume effect
spinal cord
effective FSU size
medicinsk strålningsfysik
Medical Radiation Physics

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy