Addressing the electrical degradation of 845 nm micro-transfer printed VCSILs through TCAD simulations

Zenari, M. (författare)
Università Degli Studi di Padova,University of Padua
Buffolo, M. (författare)
Università Degli Studi di Padova,University of Padua
De Santi, C. (författare)
Università Degli Studi di Padova,University of Padua
visa fler...
Goyvaerts, J. (författare)
Grabowski, Alexander, 1993 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Gustavsson, Johan, 1974 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Baets, Roel G. (författare)
Universiteit Gent,Ghent university
Larsson, Anders, 1957 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Roelkens, Gunther (författare)
Universiteit Gent,Ghent university
Meneghesso, G. (författare)
Università Degli Studi di Padova,University of Padua
Zanoni, E. (författare)
Università Degli Studi di Padova,University of Padua
Meneghini, M. (författare)
Università Degli Studi di Padova,University of Padua
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Proceedings of the International Conference on Numerical Simulation of Optoelectronic Devices, NUSOD. - 2158-3234. ; 2023-September, s. 91-92
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this work we present the electrical modeling of novel 845 nm vertical-cavity silicon-integrated lasers (VCSILs) for silicon photonics (SiPh). We tested the reliability of the devices by submitting them to high current stress, corresponding to ≈ 20xIth, to observe the degradation as a function of time. During the stress experiment, we monitored the electrical characteristics at regular intervals and we observed two separate degradation phenomena: the series resistance increment and the lowering of the turn-on voltage. Thanks to a Poisson-drift diffusion simulator we simulated the I-V characteristics and the band diagrams to interpret the degradation phenomena. The results of the simulations confirmed that the electrical degradation can be caused by the diffusion of compensation impurities originating from the p-contact layers. The same mechanism was also responsible of the optical degradation of the devices.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

VCSIL
Degradation
Silicon photonics
Diffusion
Impurities

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy