Sökning: L773:1522 2586 >
Variable Flip Angle...
Variable Flip Angle 3D Ultrashort Echo Time (UTE) T-1 Mapping of Mouse Lung: A Repeatability Assessment
-
- Alamidi, Daniel (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Philips Health Systems,University of Gothenburg
-
- Smailagic, A. (författare)
- AstraZeneca AB,AstraZeneca, UK
-
- Bidar, A. W. (författare)
- AstraZeneca AB,AstraZeneca, UK
-
visa fler...
-
- Parker, N. S. (författare)
- AstraZeneca AB,AstraZeneca, UK
-
- Olsson, M. (författare)
- AstraZeneca AB,AstraZeneca, UK
-
- Hockings, Paul, 1956 (författare)
- Chalmers University of Technology
-
- Lagerstrand, Kerstin M (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
-
- Olsson, Lars E. (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
-
visa färre...
-
(creator_code:org_t)
- 2018-03-08
- 2018
- Engelska.
-
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 48:3, s. 846-852
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://research.cha...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Lung T-1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T-1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. Purpose: To evaluate the feasibility of regional lung T-1 quantification with VFA 3D-UTE and to investigate long-and short-term T-1 repeatability in the lungs of naive mice. Field strength/Sequence: 3D free-breathing radial UTE (8 mu s) at 4.7T. Assessment: VFA 3D-UTE T-1 calculations were validated against T-1 values measured with inversion recovery (IR) in phantoms. Lung T-1 and proton density (S-0) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T-1 measurements were performed during one of the imaging sessions. Statistical Tests: Agreement in T-1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson's correlation analysis. The T-1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. Results: Good T-1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T-1 in lung and muscle showed a 5% and 3% CV (1255 +/- 63 msec and 1432 +/- 42 msec, respectively, mean +/- SD) with no changes in T-1 or S-0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T-1 and S-0. Data Conclusion: VFA 3D-UTE shows promise as a reliable T-1 mapping method that enables full lung coverage, high signal-to-noise ratio (similar to 25), and spatial resolution (300 mu m) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Physiology (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)
Nyckelord
- neurogenic pulmonary-edema
- relaxation-time
- animal-model
- mri
- isoflurane
- disease
- copd
- rats
- t1
- Radiology
- Nuclear Medicine & Medical Imaging
- ristoffersson jo
- 1991
- acta radiologica
- v32
- p426
- biomarker
- 3D radial
- Biomarker
- Longitudinal relaxation time
- Lung imaging
- Mouse
- T mapping
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas