SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Grip Helena)
 

Sökning: WFRF:(Grip Helena) > Single sensor measu...

  • Bäcklund, Tomas,1958-Umeå universitet,Radiofysik (författare)

Single sensor measurement of heel-height during the push-off phase of gait

  • Artikel/kapitelEngelska2021

Förlag, utgivningsår, omfång ...

  • 2021-11-26
  • Institute of Physics (IOP),2021
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-182776
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-182776URI
  • https://doi.org/10.1088/1361-6579/ac325cDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Previously included in thesis in manuscript form. 
  • Objective: In healthy gait a forceful push-off is needed to get an efficient leg swing and propulsion, and a high heel lift makes a forceful push-off possible. The power of the push-off is decreased with increased age and in persons with impaired balance and gait. The aim of this study was to evaluate whether a wearable equipment (Striton) and algorithms to estimate vertical heel-height during gait from a single optical distance sensor is reliable and feasible for clinical applications.Approach: To assess heel-height with the Striton system an optical distance sensor was used to measure the distance to the floor along the shank. An algorithm was created to transform this measure to a vertical distance. The heel-height was validated in an experimental setup, against a 3D motion capture system (MCS), and test-retest and day-to-day tests were performed on 10 elderly persons. As a reference material 83 elderly persons were included, and heel-height was measured before and after surgery in four patients with the neurological disorder idiopathic normal pressure hydrocephalus (iNPH).Main results: In the experimental setup the accuracy was high with a maximum error of 2% at all distances, target colours and inclination angles, and the correlation to the MCS was R = 0.94. Test-retest and day-to-day tests were equal within ±1.2 cm. Mean heel-height of the elderly persons was 16.5 ± 0.6 cm and in the patients with iNPH heel-height was increased from 11.2 cm at baseline to 15.3 cm after surgery.Significance: Striton can reliably measure heel-height during gait, with low test-retest and day-to-day variability. The system was easy to attach, and simple to use, which makes it suitable for clinical applications.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Grip, HelenaUmeå universitet,Radiofysik(Swepub:umu)heagrp96 (författare)
  • Öhberg, Fredrik,1969-Umeå universitet,Radiofysik(Swepub:umu)froh0003 (författare)
  • Sundström, NinaUmeå universitet,Radiofysik(Swepub:umu)nian0004 (författare)
  • Umeå universitetRadiofysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Physiological Measurement: Institute of Physics (IOP)42:100967-33341361-6579

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bäcklund, Tomas, ...
Grip, Helena
Öhberg, Fredrik, ...
Sundström, Nina
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Physiological Me ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy