Myocardial Oxygen Extraction Fraction Measured Using Bolus Inhalation of O-15-Oxygen Gas and Dynamic PET
-
- Lubberink, Mark (författare)
- Uppsala universitet,Avdelningen för sjukhusfysik
-
Wong, Yeun Ying (författare)
-
Raijmakers, Pieter G. H. M. (författare)
-
visa fler...
-
Schuit, Robert C. (författare)
-
Luurtsema, Gert (författare)
-
Boellaard, Ronald (författare)
-
Knaapen, Paul (författare)
-
Vonk-Noordegraaf, Anton (författare)
-
Lammertsma, Adriaan A. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2010-12-13
- 2011
- Engelska.
-
Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 52:1, s. 60-66
- Relaterad länk:
-
http://jnm.snmjourna...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.2...
-
visa färre...
Abstract
Ämnesord
Stäng
- The aim of this study was to determine the accuracy of oxygen extraction fraction (OEF) measurements using a dynamic scan protocol after bolus inhalation of O-15(2). The method of analysis was optimized by investigating potential reuse of myocardial blood flow (MBF), perfusable tissue fraction, and blood and lung spillover factors derived from separate O-15-water and (CO)-O-15 scans. Methods: Simulations were performed to assess the accuracy and precision of OEF for a variety of models in which different parameters from O-15-water and (CO)-O-15 scans were reused. Reproducibility was assessed in 8 patients who underwent one 10-min dynamic scan after bolus injection of 1.1 GBq of O-15-water, two 10-min dynamic scans after bolus inhalation of 1.4 GBq of O-15(2), and a 6-min static scan after bolus inhalation of 0.8 GBq of (CO)-O-15 for region-of-interest definition. Results: Simulations showed that accuracy and precision were lowest when all parameters were determined from the O-15(2) scan. The optimal accuracy and precision of OEF were obtained when fixing MBF, perfusable tissue fraction, and blood spillover to values derived from a O-15-water scan and estimating spillover from the pulmonary gas volume using an attenuation map. Optimal accuracy and precision were confirmed in the patient study, showing an OEF test-retest variability of 13% for the whole myocardium. Correction of spillover from pulmonary gas volume requires correction of the lung time-activity curve for pulmonary blood volume, which could equally well be obtained from a O-15-water rather than (CO)-O-15 scan. Conclusion: Measurement of OEF is possible using bolus inhalation of O-15(2) and a dynamic scan protocol, with optimal accuracy and precision when other relevant parameters, such as MBF, are derived from an additional O-15-water scan.
Nyckelord
- PET
- myocardial oxygen consumption
- myocardial blood flow
- MEDICINE