SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sornmo Leif)
 

Sökning: WFRF:(Sornmo Leif) > Considerations on P...

Considerations on Performance Evaluation of Atrial Fibrillation Detectors

Butkuviene, Monika (författare)
Kaunas University of Technology
Petrenas, Andrius (författare)
Kaunas University of Technology
Solosenko, Andrius (författare)
Kaunas University of Technology
visa fler...
Martin-Yebra, Alba (författare)
University of Zaragoza
Marozas, Vaidotas (författare)
Kaunas University of Technology
Sornmo, Leif (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2021
2021
Engelska.
Ingår i: IEEE Transactions on Biomedical Engineering. - 0018-9294. ; 68:11, s. 3250-3260
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: A large number of atrial fibrillation (AF) detectors have been published in recent years, signifying that the comparison of detector performance plays a central role, though not always consistent. The aim of this study is to shed needed light on aspects crucial to the evaluation of detection performance. Methods: Three types of AF detector, using either information on rhythm, rhythm and morphology, or segments of ECG samples, are implemented and studied on both real and simulated ECG signals. The properties of different performance measures are investigated, for example, in relation to dataset imbalance. Results: The results show that performance can differ considerably depending on the way detector output is compared to database annotations, i.e., beat-to-beat, segment-to-segment, or episode-to-episode comparison. Moreover, depending on the type of detector, the results substantiate that physiological and technical factors, e.g., changes in ECG morphology, rate of atrial premature beats, and noise level, can have a considerable influence on performance. Conclusion: The present study demonstrates overall strengths and weaknesses of different types of detector, highlights challenges in AF detection, and proposes five recommendations on how to handle data and characterize performance.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)

Nyckelord

Annotations
Atrial fibrillation
Databases
deep learning
detection
Detectors
Electrocardiography
expert-crafted detection
Monitoring
performance evaluation
performance measures
Rhythm

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy