245 | 1 0 | a Arterial diameter change measurements in premature rabbit pups using B-Mode images |
264 | 1 | c 2012 |
520 | a To further promote cardiovascular research there is a growing need for arterial characterization on small animals. Arterial wall movement measurements form the basis for most stiffness related parameters. As far as we know, previous reports on lumen diameter change measurements in small animals have required ECG triggering and cross-correlation techniques on the RF-signal using extremely high frame rate. The first aim of this study was to evaluate a novel method, ARTerIal Characterization (ARTIC), for robust diameter measurements in premature rabbit pups using conventional scanning technique (B-mode, 230 Hz). Although blood pressure is important for arterial stiffness measurements, it is often impossible to obtain without affecting the animal setup. However, arterial stiffness can also be assessed by measuring the pressure independent transition strain as recently proposed by Danpinid et al. (Ultrasonics 50, 2010: 654-665). The second aim was to investigate the feasibility of measuring transition strain in premature rabbit pups using the obtained diameter curve. The diameter was 874/82 mu m (mean/SD), CV 2.9%. The distension was 24+/-3 mu m, CV 7.3%. The transition strain was 1.55+/-0.46%, CV 12.8%. In summary, ARTIC can measure arterial diameter and distension in small animals using B-Mode images at regular frame rates. ARTIC also has a low computation time suitable for real-time implementation. Measurements of transition strain on premature rabbit pups are feasible using B-Mode images at regular frame rate. (Abstract) | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Medicinteknik0 (SwePub)2062 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Medical Engineering0 (SwePub)2062 hsv//eng |
653 | a arterial diameter | |
653 | a rabbit aorta | |
653 | a high-frequency ultrasound | |
653 | a tranistion | |
653 | a strain | |
653 | a B-Mode | |
653 | a distension | |
700 | 1 | a Erlöv, Tobiasu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-tan |
700 | 1 | a Milton, Patriku Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)es-pmi |
700 | 1 | a Sveinsdottir, Snjolaug4 aut |
700 | 1 | a Jansson, Tomasu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-tja |
700 | 1 | a Persson, Hans Wu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-hpe |
700 | 1 | a Ley, David4 aut |
700 | 1 | a Cinthio, Magnusu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-mpe |
710 | 2 | a Avdelningen för Biomedicinsk teknikb Institutionen för biomedicinsk teknik4 org |
773 | 0 | t 2012 IEEE International Ultrasonics Symposium (IUS)g , s. 922-924q <922-924 |
856 | 4 | u http://dx.doi.org/10.1109/ULTSYM.2012.0230y FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/4275366 |
856 | 4 8 | u https://doi.org/10.1109/ULTSYM.2012.0230 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.