SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sveinsdóttir Snjólaug)
 

Sökning: WFRF:(Sveinsdóttir Snjólaug) > Arterial diameter c...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004735naa a2200445 4500
001oai:lup.lub.lu.se:37eb6b04-788a-4c45-b977-ec2b619537fb
003SwePub
008160404s2012 | |||||||||||000 ||eng|
024a https://lup.lub.lu.se/record/42753662 URI
024a https://doi.org/10.1109/ULTSYM.2012.02302 DOI
040 a (SwePub)lu
041 a engb eng
042 9 SwePub
072 7a kon2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Segstedt, Simonu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-sis
2451 0a Arterial diameter change measurements in premature rabbit pups using B-Mode images
264 1c 2012
520 a To further promote cardiovascular research there is a growing need for arterial characterization on small animals. Arterial wall movement measurements form the basis for most stiffness related parameters. As far as we know, previous reports on lumen diameter change measurements in small animals have required ECG triggering and cross-correlation techniques on the RF-signal using extremely high frame rate. The first aim of this study was to evaluate a novel method, ARTerIal Characterization (ARTIC), for robust diameter measurements in premature rabbit pups using conventional scanning technique (B-mode, 230 Hz). Although blood pressure is important for arterial stiffness measurements, it is often impossible to obtain without affecting the animal setup. However, arterial stiffness can also be assessed by measuring the pressure independent transition strain as recently proposed by Danpinid et al. (Ultrasonics 50, 2010: 654-665). The second aim was to investigate the feasibility of measuring transition strain in premature rabbit pups using the obtained diameter curve. The diameter was 874/82 mu m (mean/SD), CV 2.9%. The distension was 24+/-3 mu m, CV 7.3%. The transition strain was 1.55+/-0.46%, CV 12.8%. In summary, ARTIC can measure arterial diameter and distension in small animals using B-Mode images at regular frame rates. ARTIC also has a low computation time suitable for real-time implementation. Measurements of transition strain on premature rabbit pups are feasible using B-Mode images at regular frame rate. (Abstract)
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknik0 (SwePub)2062 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineering0 (SwePub)2062 hsv//eng
653 a arterial diameter
653 a rabbit aorta
653 a high-frequency ultrasound
653 a tranistion
653 a strain
653 a B-Mode
653 a distension
700a Erlöv, Tobiasu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-tan
700a Milton, Patriku Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)es-pmi
700a Sveinsdottir, Snjolaug4 aut
700a Jansson, Tomasu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-tja
700a Persson, Hans Wu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-hpe
700a Ley, David4 aut
700a Cinthio, Magnusu Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH4 aut0 (Swepub:lu)elma-mpe
710a Avdelningen för Biomedicinsk teknikb Institutionen för biomedicinsk teknik4 org
773t 2012 IEEE International Ultrasonics Symposium (IUS)g , s. 922-924q <922-924
856u http://dx.doi.org/10.1109/ULTSYM.2012.0230y FULLTEXT
8564 8u https://lup.lub.lu.se/record/4275366
8564 8u https://doi.org/10.1109/ULTSYM.2012.0230

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy