SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0173 0835 OR L773:1522 2683
 

Sökning: L773:0173 0835 OR L773:1522 2683 > (2015-2019) > Label-free bead-bas...

Label-free bead-based metallothionein electrochemical immunosensor

Nejdl, Lukas (författare)
Nguyen, Hoai Viet (författare)
Richtera, Lukas (författare)
visa fler...
Krizkova, Sona (författare)
Guran, Roman (författare)
Masarik, Michal (författare)
Hynek, David (författare)
Heger, Zbynek (författare)
Lundberg, Karin (författare)
Erikson, Kristofer (författare)
Uppsala universitet,Fasta tillståndets fysik
Adam, Vojtech (författare)
Kizek, Rene (författare)
visa färre...
 (creator_code:org_t)
2015-07-20
2015
Engelska.
Ingår i: Electrophoresis. - : Wiley. - 0173-0835 .- 1522-2683. ; 36:16, s. 1894-1904
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A novel microfluidic label-free bead-based metallothionein immunosensors was designed. To the surface of superparamagnetic agarose beads coated with protein A, polyclonal chicken IgY specifically recognizing metallothionein (MT) were immobilized via rabbit IgG. The Brdicka reaction was used for metallothionein detection in a microfluidic printed 3D chip. The assembled chip consisted of a single copper wire coated with a thin layer of amalgam as working electrode. Optimization of MT detection using designed microfluidic chip was performed in stationary system as well as in the flow arrangement at various flow rates (0-1800 L/min). In stationary arrangement it is possible to detect MT concentrations up to 30ng/mL level, flow arrangement allows reliable detection of even lower concentration (12.5ng/mL). The assembled miniature flow chip was subsequently tested for the detection of MT elevated levels (at approx. level 100 g/mL) in samples of patients with cancer. The stability of constructed device for metallothionein detection in flow arrangement was found to be several days without any maintenance needed.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Medical Biotechnology (hsv//eng)

Nyckelord

Immunosensor
Label-free
Metallothionein
Superparamagnetic particles

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy