Sökning: L773:1759 8486 > eCLIPs bifurcation ...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03180naa a2200433 4500 | |
001 | oai:prod.swepub.kib.ki.se:146466907 | |
003 | SwePub | |
008 | 240917s2021 | |||||||||||000 ||eng| | |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:1464669072 URI |
024 | 7 | a https://doi.org/10.1136/neurintsurg-2020-0163542 DOI |
040 | a (SwePub)ki | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a De Vries, J4 aut |
245 | 1 0 | a eCLIPs bifurcation remodeling system for treatment of wide neck bifurcation aneurysms with extremely low dome-to-neck and aspect ratios: a multicenter experience |
264 | c 2020-08-11 | |
264 | 1 | b BMJ,c 2021 |
520 | a Wide necked bifurcation aneurysms (WNBA) are among the most difficult aneurysms to treat. Very low dome-to-neck (DTN) and aspect ratios provide an even greater challenge in the management of WNBAs. We present the safety and efficacy profile for endovascular clip system (eCLIPs) device in the treatment of this subset of WNBAs with very unfavorable morphologies.MethodsIn our case series, 24 patients treated at 12 international centers were taken from a larger prospective voluntary post-marketing registry of 65 patients treated with the eCLIPs device and coiling. Those who had WNBAs at either the carotid or basilar terminus with a DTN ratio <1.6 and aspect ratio <1.2 were included. Radiologic and clinical outcomes were assessed immediately after the procedure and at the latest follow-up.ResultsThe eCLIPs device was successfully deployed in 23 cases (96%). One patient (4.2%) died due to guidewire perforation distal to the implant site. No other complications were documented. After a mean follow-up of 15.8 months (range 3–40 months), good radiologic outcomes (modified Raymond–Roy classification (MRRC) scores of 1 or 2) were documented in 20 of 21 patients (95%) with follow-up data. The lone patient with an MRRC score of 3 showed coiled compaction after incomplete neck coverage with the device.ConclusionOur series of patients with aneurysms having adverse DTN and aspect ratios demonstrated that the eCLIPs device has a safety and efficacy profile comparable with currently available devices in the treatment of WNBAs. | |
700 | 1 | a Boogaarts, HD4 aut |
700 | 1 | a Sorensen, L4 aut |
700 | 1 | a Holtmannspoetter, M4 aut |
700 | 1 | a Benndorf, G4 aut |
700 | 1 | a Turowski, B4 aut |
700 | 1 | a Bohner, G4 aut |
700 | 1 | a Derakhshani, S4 aut |
700 | 1 | a Navasa, C4 aut |
700 | 1 | a van Zwam, WH4 aut |
700 | 1 | a Soderman, Mu Karolinska Institutet4 aut |
700 | 1 | a Rautio, R4 aut |
700 | 1 | a Mathys, C4 aut |
700 | 1 | a Riina, H4 aut |
700 | 1 | a Marotta, TR4 aut |
710 | 2 | a Karolinska Institutet4 org |
773 | 0 | t Journal of neurointerventional surgeryd : BMJg 13:5, s. 438-+q 13:5<438-+x 1759-8486x 1759-8478 |
856 | 4 | u https://jnis.bmj.com/content/neurintsurg/early/2020/08/10/neurintsurg-2020-016354.full.pdf |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:146466907 |
856 | 4 8 | u https://doi.org/10.1136/neurintsurg-2020-016354 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy