Pre-transplantation ³¹P-magnetic resonance spectroscopy for quality assessment of human pancreatic grafts : A feasibility study

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2017
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-315894
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-315894URI
  • https://doi.org/10.1016/j.mri.2017.02.004DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Title in WOS: Pre-transplantation P-31-magnetic resonance spectroscopy for quality assessment of human pancreatic grafts - A feasibility study
  • Objective: To investigate the feasibility of using (31)P-MRS for objective non-invasive quality assessment of human pancreas grafts prior to transplantation or islet isolation.Materials and methods: Pancreata from 5 human donors, 3 males and 2 females, aged 49-78years, with body mass index (BMI) 22-31kg/m(2), were included. Pancreata were perfused with histidine-tryptophan-ketoglutarate solution during procurement and stored in hypothermic condition (4°C) for 21-44h. During the period of hypothermic storage repeated spectra were obtained for each graft by (31)P-MRS (1.5Tesla) to measure the cold ischemia time (CIT) dependent changes of the phosphorous metabolites adenosine triphosphate (ATP), phosphomonoesters (PME), phosphodiesters (PDE) and inorganic phosphate (Pi), in the grafts. Graft temperature was measured immediately before and after MR-examination. Reference spectrum for non-viable tissue was obtained after graft exposure to room temperature.Results: PME/Pi, PDE/Pi and ATP/Pi spectral intensities ratios decreased with increasing CIT, reflecting the decreased viability of the grafts. PME/Pi ratio was the most discriminatory variable at prolonged CIT. (31)P-MRS could be performed without significantly increasing graft temperature.Conclusions: (31)P-MRS may provide quantitative parameters for evaluating graft viability ex vivo, and is a promising tool for objective non-invasive assessment of the quality of human pancreas grafts prior to transplantation or islet isolation.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Weis, JanUppsala universitet,Radiologi(Swepub:uu)janweis (författare)
  • Johansson, LarsUppsala universitet,Radiologi(Swepub:uu)larsjoha (författare)
  • Korsgren, OlleUppsala universitet,Klinisk immunologi(Swepub:uu)ollekors (författare)
  • Ahlström, HåkanUppsala universitet,Radiologi(Swepub:uu)hakanahl (författare)
  • Uppsala universitetRadiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Magnetic Resonance Imaging: Elsevier BV39, s. 98-1020730-725X1873-5894

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Carlbom, Lina
Weis, Jan
Johansson, Lars
Korsgren, Olle
Ahlström, Håkan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy