Sökning: WFRF:(Ghosh Swagatha 1987) >
Current status and ...
Current status and future opportunities for serial crystallography at MAX IV Laboratory
-
- Shilova, Anastasiia (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory,MAX IV Laboratory, Lund University, Lund, Sweden
-
- Lebrette, Hugo (författare)
- Stockholm University,Stockholms universitet,Institutionen för biokemi och biofysik,Department of Biochemistry and Biophysics, Stockholm University, Stockholm, Sweden
-
- Aurelius, Oskar (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory,MAX IV Laboratory, Lund University, Lund, Sweden
-
visa fler...
-
- Nan, Jie (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Welin, Martin (författare)
- SARomics Biostructures AB
-
- Kovacic, Rebeka (författare)
- SARomics Biostructures AB
-
- Ghosh, Swagatha, 1987 (författare)
- Gothenburg University,Göteborgs universitet,University of Gothenburg,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology
-
- Safari, Cecilia, 1989 (författare)
- Gothenburg University,Göteborgs universitet,University of Gothenburg,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology
-
- Friel, Ross J. (författare)
- Högskolan i Halmstad,Halmstad University,Centrum för forskning om inbyggda system (CERES)
-
- Milas, Mirko (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Matej, Zdenek (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Högbom, Martin (författare)
- Stockholm University,Stockholms universitet,Institutionen för biokemi och biofysik
-
- Brändén, Gisela, 1975 (författare)
- Gothenburg University,Göteborgs universitet,University of Gothenburg,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology
-
- Kloos, Marco (författare)
- European XFEL GmbH
-
- Shoeman, Robert L. (författare)
- Max-Planck-Institut für Medizinische Forschung
-
- Doak, Bruce (författare)
- Max-Planck-Institut für Medizinische Forschung
-
- Ursby, Thomas (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Hakansson, Maria (författare)
- SARomics Biostructures AB
-
- Logan, Derek T. (författare)
- SARomics Biostructures AB
-
- Müller, Uwe (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory,Helmholtz Association of German Research Centers
-
visa färre...
-
(creator_code:org_t)
- Chichester : Wiley-Blackwell, 2020
- 2020
- Engelska.
-
Ingår i: Journal of Synchrotron Radiation. - Chichester : Wiley-Blackwell. - 0909-0495 .- 1600-5775. ; 27, s. 1095-1102
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
http://dx.doi.org/10... (free)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
https://urn.kb.se/re...
-
https://gup.ub.gu.se...
-
visa färre...
Abstract
Ämnesord
Stäng
- Over the last decade, serial crystallography, a method to collect complete diffraction datasets from a large number of microcrystals delivered and exposed to an X-ray beam in random orientations at room temperature, has been successfully implemented at X-ray free-electron lasers and synchrotron radiation facility beamlines. This development relies on a growing variety of sample presentation methods, including different fixed target supports, injection methods using gas-dynamic virtual-nozzle injectors and high-viscosity extrusion injectors, and acoustic levitation of droplets, each with unique requirements. In comparison with X-ray free-electron lasers, increased beam time availability makes synchrotron facilities very attractive to perform serial synchrotron X-ray crystallography (SSX) experiments. Within this work, the possibilities to perform SSX at BioMAX, the first macromolecular crystallography beamline at studies from the SSX user program: an implementation of a high-viscosity extrusion injector to perform room temperature serial crystallography at BioMAX using two solid supports - silicon nitride membranes (Silson, UK) and XtalTool (Jena Bioscience, Germany). Future perspectives for the dedicated serial crystallography beamline MicroMAX at MAX IV Laboratory, which will provide parallel and intense micrometre-sized X-ray beams, are discussed.
Ämnesord
- NATURVETENSKAP -- Biologi (hsv//swe)
- NATURAL SCIENCES -- Biological Sciences (hsv//eng)
- NATURVETENSKAP -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)
- NATURVETENSKAP -- Biologi -- Strukturbiologi (hsv//swe)
- NATURAL SCIENCES -- Biological Sciences -- Structural Biology (hsv//eng)
Nyckelord
- serial crystallography
- macromolecular crystallography
- sample delivery
- high-viscosity injectors
- high-viscosity injectors
- macromolecular crystallography
- sample delivery
- serial crystallography
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Shilova, Anastas ...
-
Lebrette, Hugo
-
Aurelius, Oskar
-
Nan, Jie
-
Welin, Martin
-
Kovacic, Rebeka
-
visa fler...
-
Ghosh, Swagatha, ...
-
Safari, Cecilia, ...
-
Friel, Ross J.
-
Milas, Mirko
-
Matej, Zdenek
-
Högbom, Martin
-
Brändén, Gisela, ...
-
Kloos, Marco
-
Shoeman, Robert ...
-
Doak, Bruce
-
Ursby, Thomas
-
Hakansson, Maria
-
Logan, Derek T.
-
Müller, Uwe
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Biologi
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
-
och Atom och molekyl ...
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Biologi
-
och Strukturbiologi
- Artiklar i publikationen
-
Journal of Synch ...
- Av lärosätet
-
Stockholms universitet
-
Lunds universitet
-
Högskolan i Halmstad
-
Göteborgs universitet