Detection of Needle Dislodgement Using Extracorporeal Pressure Signals : A Feasibility Study
-
- Holmer, Mattias (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Baxter Medical AB
-
- Olde, Bo (author)
- Baxter Medical AB
-
- Sandberg, Frida (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
show more...
-
- Sörnmo, Leif (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
show less...
-
(creator_code:org_t)
- 2020
- 2020
- English 9 s.
-
In: ASAIO Journal. - 1538-943X. ; 66:4, s. 454-462
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Venous needle dislodgement (VND) during dialysis is a rarely occurring adverse event, which becomes life-threatening if not handled promptly. Because the standard venous pressure alarm, implemented in most dialysis machines, has low sensitivity, a novel approach using extracted cardiac information to detect needle dislodgement is proposed. Four features are extracted from the arterial and venous pressure signals of the dialysis machine, characterizing the mean venous pressure, the venous cardiac pulse pressure, the time delay, and the correlation between the two pressure signals. The features serve as input to a support vector machine (SVM), which determines whether dislodgement has occurred. The SVM is first trained on a set of laboratory data, and then tested on another set of laboratory data as well as on a small data set from clinical hemodialysis sessions. The results show that dislodgement can be detected after 12-17 s, corresponding to 24-143 ml blood loss. The standard venous pressure alarm used in clinical routine only detects 50% of the VNDs, whereas the novel method detects all VNDs and has a false alarm rate of 0.12 per hour, provided that the amplitude of the extracted cardiac pressure signal exceeds 1 mmHg. The results are promising; however, the method needs to be tested on a larger set of clinical data to better establish its performance.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)