Sökning: WFRF:(Treanor Darren) >
Development and Eva...
Development and Evaluation of a Novel Point-of-Use Quality Assurance Tool for Digital Pathology
-
- Clarke, Emily L. (författare)
- Univ Leeds, England; Leeds Teaching Hosp NHS Trust, England
-
- Brettle, David (författare)
- Leeds Teaching Hosp NHS Trust, England
-
- Sykes, Alexander (författare)
- Univ Leeds, England
-
visa fler...
-
- Wright, Alexander (författare)
- Univ Leeds, England
-
- Boden, Anna (författare)
- Linköpings universitet,Avdelning för neurobiologi,Medicinska fakulteten,Region Östergötland, Klinisk patologi
-
- Treanor, Darren (författare)
- Linköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Klinisk patologi,Univ Leeds, England
-
visa färre...
-
(creator_code:org_t)
- COLL AMER PATHOLOGISTS, 2019
- 2019
- Engelska.
-
Ingår i: Archives of Pathology & Laboratory Medicine. - : COLL AMER PATHOLOGISTS. - 0003-9985 .- 1543-2165. ; 143:10, s. 1246-1255
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.5...
-
visa färre...
Abstract
Ämnesord
Stäng
- Context.-Flexible working at diverse or remote sites is a major advantage when reporting using digital pathology, but currently there is no method to validate the clinical diagnostic setting within digital microscopy. Objective.-To develop a preliminary Point-of-Use Quality Assurance (POUQA) tool designed specifically to validate the diagnostic setting for digital microscopy. Design.-We based the POUQA tool on the red, green, and blue (RGB) values of hematoxylin-eosin. The tool used 144 hematoxylin-eosin-colored, 5x5-cm patches with a superimposed random letter with subtly lighter RGB values from the background color, with differing levels of difficulty. We performed an initial evaluation across 3 phases within 2 pathology departments: 1 in the United Kingdom and 1 in Sweden. Results.-In total, 53 experiments were conducted across all phases resulting in 7632 test images viewed in all. Results indicated that the display, the users visual system, and the environment each independently impacted performance. Performance was improved with reduction in natural light and through use of medical-grade displays. Conclusions.-The use of a POUQA tool for digital microscopy is essential to afford flexible working while ensuring patient safety. The color-contrast test provides a standardized method of comparing diagnostic settings for digital microscopy. With further planned development, the color-contrast test may be used to create a "Verified Login" for diagnostic setting validation.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas