SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0009 8981 OR L773:1873 3492
 

Sökning: L773:0009 8981 OR L773:1873 3492 > A hyaluronan-loadin...

A hyaluronan-loading test applied to patients with liver and joint diseases

Lindqvist, Ulla (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Reumatologi
Groth, Torgny (författare)
Uppsala universitet,Biomedicinsk informatik och teknik
Lööf, L. (författare)
visa fler...
Hellsing, K. (författare)
visa färre...
 (creator_code:org_t)
1992
1992
Engelska.
Ingår i: Clinica Chimica Acta. - 0009-8981 .- 1873-3492. ; 210:1-2, s. 119-132
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The serum hyaluronan disappearance data, after an intravenous bolus injection of hyaluronan, were evaluated in terms of model-based parameters. The loading test was performed in 10 healthy persons (basal serum hyaluronan concentration, C0, 24.9 +/- 8.9 micrograms/l [mean +/- S.D.]), 6 patients with joint disease (62.3 +/- 41.1 micrograms/l) and 19 patients with liver disease (206 +/- 214 micrograms/l). The highest maximum Michaelis-Menten elimination rate (Vmax = 287 +/- 86 micrograms/min) was found in patients with joint disease, significantly higher than in healthy persons (Vmax = 179 +/- 16, P = 0.0015) and in patients with liver disease (Vmax = 149 +/- 59, P = 0.0002). C0 and Vmax were evaluated as discriminants for assessment of residual liver function. In patients with liver disease C0 correlated with liver function score (r = 0.875, P < 0.0001) and serum albumin concentration (r = -0.813, P < 0.0001). The Vmax parameter did not correlate with conventional liver function tests or with the liver score but a significantly negative correlation of Vmax with C0 was found in patients with liver disease. A combination of the C0 level and the Vmax parameter was found to discriminate between healthy persons, patients with joint disease and patients with liver disease and should be of benefit in separating patients, with or without elevated serum hyaluronan levels, into groups having increased influx or reduced elimination, respectively, of circulating hyaluronan.

Nyckelord

Elimination parameters
Healthy; Hyaluronan
Hyaluronate
Hyaluronic acid
Liver disease
Loading test
Rheumatoid arthritis
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lindqvist, Ulla
Groth, Torgny
Lööf, L.
Hellsing, K.
Artiklar i publikationen
Clinica Chimica ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy