SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Bamberg K)
 

Search: WFRF:(Bamberg K) > Preclinical x-ray d...

Preclinical x-ray dark-field radiography for pulmonary emphysema evaluation

Yaroshenko, A. (author)
Technical University of Munich
Meinel, F. G. (author)
University Hospital Munich
Bech, M. (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Technical University of Munich
show more...
Tapfer, A. (author)
Technical University of Munich
Velroyen, A. (author)
Technical University of Munich
Schleede, S. (author)
Technical University of Munich
Muller, M. (author)
Technical University of Munich
Auweter, S. (author)
University Hospital Munich
Bohla, A. (author)
Helmholtz Zentrum München
Yildirim, A. O. (author)
Helmholtz Zentrum München
Nikolaou, K. (author)
University Hospital Munich
Bamberg, F. (author)
University Hospital Munich
Eickelberg, O. (author)
Helmholtz Zentrum München
Reiser, M. (author)
University Hospital Munich
Pfeiffer, F. (author)
Technical University of Munich
show less...
 (creator_code:org_t)
2013
2013
English.
In: ISBI 2013 - 2013 IEEE 10th International Symposium on Biomedical Imaging : From Nano to Macro - From Nano to Macro. - 1945-7928 .- 1945-8452. - 9781467364553 - 9781467364560 ; , s. 370-373
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Pulmonary emphysema is a widespread disorder characterized by irreversible destruction of alveolar walls. The spatial distribution of the disease, so far, could only be obtained using an x-ray CT scan, implying a high patient dose. X-ray scattering on alveolar structures is measured in the dark-field signal. The signal is dependent on the size of alveoli and therefore, a combination of absorption and dark-field signal is explored for mapping the distribution of emphysema in the lung on x-ray projection images. In this study three excised murine lungs with pulmonary emphysema and three control samples were imaged using a compact, cone-beam, small-animal x-ray dark-field scanner with a polychromatic source. Statistical analysis of the results, based on a combination of transmission and dark-field signals, revealed a distinct difference between emphysematous and control samples. Subsequently, the distribution of emphysema was mapped out per-pixel for the lungs and showed good agreement with histological findings.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

dark-field
emphysema
grating interferometer
phase-contrast
x-ray

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view