SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1617 7959 OR L773:1617 7940
 

Sökning: L773:1617 7959 OR L773:1617 7940 > Trabecular deformat...

Trabecular deformations during screw pull-out : a micro-CT study of lapine bone

Joffre, Thomas (författare)
Uppsala universitet,Tillämpad materialvetenskap
Isaksson, Per (författare)
Uppsala universitet,Tillämpad mekanik
Procter, Philip (författare)
Uppsala universitet,Tillämpad materialvetenskap
visa fler...
Persson, Cecilia (författare)
Uppsala universitet,Tillämpad materialvetenskap
visa färre...
 (creator_code:org_t)
2017-03-06
2017
Engelska.
Ingår i: Biomechanics and Modeling in Mechanobiology. - : SPRINGER HEIDELBERG. - 1617-7959 .- 1617-7940. ; 16:4, s. 1349-1359
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bone of rabbit femurs and then pulled out from the bone inside a computational tomography scanner. The tests were interrupted at certain load steps to acquire 3D images. The images were then analysed with a digital volume correlation technique to estimate deformation and strain fields inside the bone during the tests. The results indicate that the highest shear strains are concentrated between the inner and outer thread diameter, whereas compressive strains are found at larger distances from the screw. Tensile strains were somewhat smaller. Strain concentrations and the location of trabecular failures provide experimental information that could be used in the development of new screw designs and/or to validate numerical simulations.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk material- och protesteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Materials (hsv//eng)

Nyckelord

Screws
Implants
Trabecular bone
Pull-out test
Digital volume correlation
Micro-CT

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Joffre, Thomas
Isaksson, Per
Procter, Philip
Persson, Cecilia
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk materi ...
Artiklar i publikationen
Biomechanics and ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy