SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Wetzel F.)
 

Search: WFRF:(Wetzel F.) > GEOTRACES inter-cal...

  • Grasse, Patricia (author)

GEOTRACES inter-calibration of the stable silicon isotope composition of dissolved silicic acid in seawater

  • Article/chapterEnglish2017

Publisher, publication year, extent ...

  • 2017
  • Royal Society of Chemistry (RSC),2017
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:su-142447
  • https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-142447URI
  • https://doi.org/10.1039/c6ja00302hDOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • The first inter-calibration study of the stable silicon isotope composition of dissolved silicic acid in seawater, delta Si-30(OH)(4), is presented as a contribution to the international GEOTRACES program. Eleven laboratories from seven countries analyzed two seawater samples from the North Pacific subtropical gyre (Station ALOHA) collected at 300 m and at 1000 m water depth. Sampling depths were chosen to obtain samples with a relatively low (9 mmol L-1, 300 m) and a relatively high (113 mmol L-1, 1000 m) silicic acid concentration as sample preparation differs for low- and highconcentration samples. Data for the 1000 m water sample were not normally distributed so the median is used to represent the central tendency for the two samples. Median delta Si-30(OH)(4) values of +1.66& for the low-concentration sample and +1.25& for the high-concentration sample were obtained. Agreement among laboratories is overall considered very good; however, small but statistically significant differences among the mean isotope values obtained by different laboratories were detected, likely reflecting inter-laboratory differences in chemical preparation including pre-concentration and purification methods together with different volumes of seawater analyzed, and the use of different mass spectrometers including the Neptune MC-ICP-MS (Thermo Fisher (TM), Germany), the Nu Plasma MC-ICP-MS (Nu Instruments (TM), Wrexham, UK), and the Finnigan (TM) (now Thermo Fisher (TM), Germany) MAT 252 IRMS. Future studies analyzing delta Si-30(OH)(4) in seawater should also analyze and report values for these same two reference waters in order to facilitate comparison of data generated among and within laboratories over time.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Brzezinski, Mark A. (author)
  • Cardinal, Damien (author)
  • de Souza, Gregory F. (author)
  • Andersson, Per (author)
  • Closset, Ivia (author)
  • Cao, Zhimian (author)
  • Dai, Minhan (author)
  • Ehlert, Claudia (author)
  • Estrade, Nicolas (author)
  • Francois, Roger (author)
  • Frank, Martin (author)
  • Jiang, Guibin (author)
  • Jones, Janice L. (author)
  • Kooijman, Ellen (author)
  • Liu, Qian (author)
  • Lu, Dawei (author)
  • Pahnke, Katharina (author)
  • Ponzevera, Emanuel (author)
  • Schmitt, Melanie (author)
  • Sun, XiaoleStockholms universitet,Institutionen för miljövetenskap och analytisk kemi(Swepub:su)xisu8236 (author)
  • Sutton, Jill N. (author)
  • Thil, Francois (author)
  • Weis, Dominique (author)
  • Wetzel, Florian (author)
  • Zhang, Anyu (author)
  • Zhang, Jing (author)
  • Zhang, Zhouling (author)
  • Stockholms universitetInstitutionen för miljövetenskap och analytisk kemi (creator_code:org_t)

Related titles

  • In:Journal of Analytical Atomic Spectrometry: Royal Society of Chemistry (RSC)32:3, s. 562-5780267-94771364-5544

Internet link

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close