SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Gustafsson Ingemar)
 

Sökning: WFRF:(Gustafsson Ingemar) > Patient experience ...

Patient experience and repeatability of measurements made with the Pentacam HR in patients with keratoconus

Gustafsson, Ingemar (författare)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Klinisk forskning inom hornhinnesjukdomar,Forskargrupper vid Lunds universitet,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Clinical research in corneal disease and disorders,Lund University Research Groups
Bizios, Dimitrios (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
Ivarsen, Anders (författare)
Aarhus University Hospital
visa fler...
Hjortdal, Jesper (författare)
Aarhus University Hospital
visa färre...
 (creator_code:org_t)
2023
2023
Engelska 1 s.
Ingår i: BMC Ophthalmology. - 1471-2415. ; 23:1, s. 201-201
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: To investigate whether the repeatability of measurements with the Pentacam HR in patients with keratoconus is improved by patients gaining more experience of the measurement situation. Such an improvement could enhance the accuracy with which progressive keratoconus can be detected. METHODS: Four replicate measurements were performed on Day 0 and on Day 3. Parameters commonly used in the diagnosis of progressive keratoconus were included in the analysis, namely the flattest central keratometry value (K1), the steepest central keratometry value (K2), the maximum keratometry value (Kmax), and the parameters A, B and C from the Belin ABCD Progression Display. In addition, quality parameters used by the Pentacam HR to assess the quality of the measurements were included, namely the analysed area (front + back), 3D (front + back), XY, Z, and eye movements. RESULTS: Neither the diagnostic parameters nor the quality parameters showed any statistically significant improvement on Day 3 compared to Day 0. The quality parameter "eye movements" deteriorated significantly with increasing Kmax. CONCLUSION: Gaining experience of the measurement situation did not increase the accuracy of the measurements. Further investigations should be performed to determine whether the increasing number of eye movements with increasing disease severity has a negative effect on the repeatability of the measurements.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Keratoconus
Pentacam HR
Repeatability
Tomography

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gustafsson, Inge ...
Bizios, Dimitrio ...
Ivarsen, Anders
Hjortdal, Jesper
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
BMC Ophthalmolog ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy