Sökning: WFRF:(Pomp Stephan) > Comparison of digit...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02846naa a2200445 4500 | |
001 | oai:DiVA.org:uu-142438 | |
003 | SwePub | |
008 | 110114s2010 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-1424382 URI |
024 | 7 | a https://doi.org/10.1016/j.nima.2010.09.1262 DOI |
040 | a (SwePub)uu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Al-Adili, Aliu Uppsala universitet,Tillämpad kärnfysik4 aut0 (Swepub:uu)alial125 |
245 | 1 0 | a Comparison of digital and analogue data acquisition systems for nuclear spectroscopy |
264 | 1 | b Elsevier BV,c 2010 |
338 | a print2 rdacarrier | |
520 | a In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient αparticle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly αactive actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong αemitter, when applying the αparticle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded off-line analysis and reduces the number of electronic modules drastically, leading to an increased stability against electronic drifts when long measurement times are required. | |
650 | 7 | a NATURVETENSKAPx Fysik0 (SwePub)1032 hsv//swe |
650 | 7 | a NATURAL SCIENCESx Physical Sciences0 (SwePub)1032 hsv//eng |
653 | a Fission | |
653 | a 234-U(n | |
653 | a f) | |
653 | a 235-U(n | |
653 | a f) | |
653 | a Digital | |
653 | a Analogue | |
653 | a Ionization chambers | |
653 | a Physics | |
653 | a Fysik | |
700 | 1 | a Hambsch, Franz-Josefu EC-JRC, IRMM, Geel, Belgium4 aut |
700 | 1 | a Oberstedt, Stephanu EC-JRC, IRMM, Geel, Belgium4 aut |
700 | 1 | a Pomp, Stephanu Uppsala universitet,Tillämpad kärnfysik4 aut0 (Swepub:uu)steppomp |
700 | 1 | a Zeynalov, Shakiru JINR, Dubna, Russia4 aut |
710 | 2 | a Uppsala universitetb Tillämpad kärnfysik4 org |
773 | 0 | t Nuclear Instruments and Methods in Physics Research Section Ad : Elsevier BVg 624:3, s. 684-690q 624:3<684-690x 0168-9002x 1872-9576 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-142438 |
856 | 4 8 | u https://doi.org/10.1016/j.nima.2010.09.126 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy