Sökning: WFRF:(Belis Jan) >
Structural analysis...
Structural analysis of slender glass panel subjected to static and impact loading
-
- Kozłowski, Marcin (författare)
- Lund University,Lunds universitet,Byggnadsmekanik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Structural Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH,Silesian University of Technology
-
- Kinsella, David (författare)
- Lund University,Lunds universitet,Byggnadsmekanik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Structural Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Persson, Kent (författare)
- Lund University,Lunds universitet,Byggnadsmekanik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Structural Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
- Kubica, Jan (författare)
- Silesian University of Technology
-
- Hulimka, Jacek (författare)
- Silesian University of Technology
-
Louter, Christian (redaktör/utgivare)
-
Bos, Freek (redaktör/utgivare)
-
Belis, Jan (redaktör/utgivare)
-
Veer, Fred (redaktör/utgivare)
-
Nijsse, Rob (redaktör/utgivare)
-
visa färre...
-
(creator_code:org_t)
- 2018
- 2018
- Engelska 8 s.
-
Ingår i: Challenging Glass 6 : Conference on Architectural and Structural Applications of Glass, CGC 2018 - Proceedings - Conference on Architectural and Structural Applications of Glass, CGC 2018 - Proceedings. - 9789463660440 ; , s. 427-434
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.7...
-
visa färre...
Abstract
Ämnesord
Stäng
- Slender glass panels are widely used as storefronts and indoor separating walls in shopping malls and public buildings. To ensure that the design and construction is technically safe for general use and that it meets current and accepted technical standards, in-situ testing is required by the building administrator or authorities. A case study was performed of an indoor glass lantern in a public building made from slender two-side supported glass panels with a complex geometry. It provides structural assessments and results of in-situ experiments including static loading and soft body impact test. Results from numerical simulations of impact loading on the glass panels complementing the experimental results are also presented. The in-situ testing proved that the structural design meets current standards regarding the static loading. The soft body impact test proved the safety of the intact panel and the panel with one ply deliberately broken. The numerical study showed that, for a more complicated geometry, the stress distribution can dramatically change over time and that stress concentrations can develop at certain locations at a late stage in the impact history.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Building Technologies (hsv//eng)
Nyckelord
- Architectural glass
- Glass
- Impact loading
- In-situ testing
- Numerical simulations
- Static loading
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Kozłowski, Marci ...
-
Kinsella, David
-
Persson, Kent
-
Kubica, Jan
-
Hulimka, Jacek
-
Louter, Christia ...
-
visa fler...
-
Bos, Freek
-
Belis, Jan
-
Veer, Fred
-
Nijsse, Rob
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Samhällsbyggnads ...
-
och Husbyggnad
- Artiklar i publikationen
-
Challenging Glas ...
- Av lärosätet
-
Lunds universitet