SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Gomis Berenguer Alicia)
 

Sökning: WFRF:(Gomis Berenguer Alicia) > (2023) > Portable All-in-One...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003741naa a2200361 4500
001oai:DiVA.org:kth-330029
003SwePub
008230627s2023 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-3300292 URI
024a https://doi.org/10.1021/acs.analchem.2c053072 DOI
040 a (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Chen, Chenu KTH,Tillämpad fysikalisk kemi4 aut0 (Swepub:kth)u1c3hj8e
2451 0a Portable All-in-One Electrochemical Actuator-Sensor System for the Detection of Dissolved Inorganic Phosphorus in Seawater
264 c 2023-02-01
264 1b American Chemical Society (ACS),c 2023
338 a print2 rdacarrier
500 a QC 20230627
520 a We present a methodology for the detection of dissolved inorganic phosphorous (DIP) in seawater using an electrochemically driven actuator-sensor system. The motivation for this work stems from the lack of tangible solutions for the in situ monitoring of nutrients in water systems. It does not require the addition of any reagents to the sample and works under mild polarization conditions, with the sample confined to a thin-layer compartment. Subsequent steps include the oxidation of polyaniline to lower the pH, the delivery of molybdate via a molybdenum electrode, and the formation of an electroactive phosphomolybdate complex from DIP species. The phosphomolybdate complex is ultimately detected by either cyclic voltammetry (CV) or square wave voltammetry (SWV). The combined release of protons and molybdate consistently results in a sample pH < 2 as well as a sufficient excess of molybdate, fulfilling the conditions required for the stoichiometric detection of DIP. The current of the voltammetric peak was found to be linearly related to DIP concentrations between 1 and 20 μM for CV and 0.1 and 20 μM for SWV, while also being selective against common silicate interference. The analytical application of the system was demonstrated by the validated characterization of five seawater samples, revealing an acceptable degree of difference compared to chromatography measurements. This work paves the way for the future DIP digitalization in environmental waters by in situ electrochemical probes with unprecedented spatial and temporal resolution. It is expected to provide real-time data on anthropogenic nutrient discharges as well as the improved monitoring of seawater restoration actions.
650 7a NATURVETENSKAPx Kemix Analytisk kemi0 (SwePub)104012 hsv//swe
650 7a NATURAL SCIENCESx Chemical Sciencesx Analytical Chemistry0 (SwePub)104012 hsv//eng
700a Wiorek, Alexanderu KTH,Tillämpad fysikalisk kemi4 aut0 (Swepub:kth)u1r5mhmr
700a Gomis Berenguer, Alicia4 aut
700a Crespo, Gaston A.,d 1980-u KTH,Tillämpad fysikalisk kemi,UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain, Avda. Andres Hernandez Ros 14 aut0 (Swepub:kth)u185cj5g
700a Cuartero, Maria,c PhD,d 1984-u KTH,Tillämpad fysikalisk kemi,UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain, Avda. Andres Hernandez Ros 14 aut0 (Swepub:kth)u1lfp38j
710a KTHb Tillämpad fysikalisk kemi4 org
773t Analytical Chemistryd : American Chemical Society (ACS)g 95:8, s. 4180-4189q 95:8<4180-4189x 0003-2700x 1520-6882
856u https://doi.org/10.1021/acs.analchem.2c05307y Fulltext
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-330029
8564 8u https://doi.org/10.1021/acs.analchem.2c05307

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy