SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jordung U.)
 

Sökning: WFRF:(Jordung U.) > Dose reduction in m...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003346naa a2200697 4500
001oai:DiVA.org:kth-157433
003SwePub
008141209s2004 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-1574332 URI
024a https://doi.org/10.1117/12.5306492 DOI
040 a (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a kon2 swepub-publicationtype
100a Thunberg, S.4 aut
2451 0a Dose reduction in mammography with photon counting imaging
264 1b SPIE,c 2004
338 a print2 rdacarrier
500 a QC 20141212
520 a The purpose of this study was to investigate if the glandular dose to the breast in mammography can significantly be reduced without compromising image quality, when using photon counting technology, in a multi-slit scanning photon counting detector, compared to a conventional film mammography system and commercial available digital mammography systems with TFT-array detectors. A CDMAM phantom study, with two different thicknesses of additional PMMA absorber, 4 cm and 7 cm respectively, has shown that multi-slit scanning photon counting detector technology can reduce the dose, without reducing the image quality. This comparison was made to two commercial available digital mammography systems Senographe 2000D (from GEMS) and Selenia (from Lorad). The results show that dose can be reduced with 63% to 77%, depending on object thickness, when using XCT for mammography. This dose reduction has also been verified clinically through a small pilot study with patients and specimen, where the comparison was made between XCT and film.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a CDMAM phantom
653 a Digital mammography
653 a Dose reduction
653 a Photon counting
653 a Arrays
653 a Gold
653 a Image quality
653 a Oncology
653 a Polymethyl methacrylates
653 a Radiation detectors
653 a Thickness measurement
653 a X ray analysis
653 a CDMAM phantoms
653 a Mammography
700a Adelöw, L.4 aut
700a Blom, O.4 aut
700a Cöster, A.4 aut
700a Egerström, J.4 aut
700a Eklund, M.4 aut
700a Egnell, P.4 aut
700a Francke, T.4 aut
700a Jordung, U.4 aut
700a Kristoffersson, T.4 aut
700a Lindman, K.4 aut
700a Lindqvist, L.4 aut
700a Marchal, D.4 aut
700a Olla, H.4 aut
700a Penton, E.4 aut
700a Peskov, Vladimiru KTH,Fysik4 aut0 (Swepub:kth)u157hfnu
700a Rantanen, J.4 aut
700a Solokov, S.4 aut
700a Svedenhag, P.4 aut
700a Ullberg, C.4 aut
700a Weber, N.4 aut
710a KTHb Fysik4 org
773t Proceedings of SPIE - The International Society for Optical Engineeringd : SPIEg , s. 457-465q <457-465
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-157433
8564 8u https://doi.org/10.1117/12.530649

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy