A sound insulation prediction model for floor structures in wooden buildings using neural networks approach

Bader Eddin, Mohamad (författare)
University of Quebec at Chicoutimi
Menard, Sylvain (författare)
University of Quebec at Chicoutimi
Bard, Delphine (författare)
Lund University,Lunds universitet,Teknisk akustik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Engineering Acoustics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Kouyoumji, Jean Luc (författare)
Vardaxis, Nikolas Georgios (författare)
Lund University,Lunds universitet,Teknisk akustik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Engineering Acoustics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
Dare, Tyler (redaktör/utgivare)
Bolton, Stuart (redaktör/utgivare)
Davies, Patricia (redaktör/utgivare)
Xue, Yutong (redaktör/utgivare)
Ebbitt, Gordon (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
2021
2021
Engelska.
Ingår i: Proceedings of INTER-NOISE 2021 - 2021 International Congress and Exposition of Noise Control Engineering. - 0736-2935. - 9781732598652
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Reliable prediction tools are yet to be developed for estimating the accurate acoustic performance of lightweight structures, which are vital especially in the design process. This paper presents a sound insulation prediction model based on artificial Neural Networks (NN) to estimate acoustic performance for airborne and impact sound insulation of floor structures. At an initial stage, the prediction model was developed and tested for a small amount of data, specifically 67 laboratory measurement curves in one third octave bands. The results indicate that the model can predict the weighted airborne reduction index Rw for various floors with a maximum error of 1 dB. The accuracy decreases with errors up to 9 dB for the weighted index for impact sound Ln,w, in cases of complex floor configurations due to large error deviations in high frequency bands between the real and estimated values. The model also shows a very good accuracy in predicting the airborne and impact sound insulation curves in the low frequencies, which are of higher interest usually in building acoustics.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

Airborne sound
Building acoustics
Impact sound
Neural networks
Prediction model

Publikations- och innehållstyp

kon (ämneskategori)
vet (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy