Sökning: WFRF:(Musahl V)
> (2016) >
Objective measures ...
Objective measures on knee instability: dynamic tests: a review of devices for assessment of dynamic knee laxity through utilization of the pivot shift test
-
- Sundemo, David (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
-
Alentorn-Geli, E. (författare)
-
Hoshino, Y. (författare)
-
visa fler...
-
Musahl, V. (författare)
-
- Karlsson, Jón, 1953 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
-
- Samuelsson, Kristian, 1977 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
-
visa färre...
-
(creator_code:org_t)
- 2016-03-17
- 2016
- Engelska.
-
Ingår i: Current Reviews in Musculoskeletal Medicine. - : Springer Science and Business Media LLC. - 1935-973X .- 1935-9748. ; 9:2, s. 148-159
- Relaterad länk:
-
https://europepmc.or...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Current reconstructive methods used after anterior cruciate ligament (ACL) injury do not entirely restore native knee kinematics. Evaluation of dynamic knee laxity is important to accurately diagnose ACL deficiency, to evaluate reconstructive techniques, and to construct treatment algorithms for patients with ACL injury. The purpose of this study is to present recent progress in evaluation of dynamic knee laxity through utilization of the pivot shift test. A thorough electronic search was performed and relevant studies were assessed. Certain dynamic knee laxity measurement methods have been present for over 10 years (Navigation system, Electromagnetic sensor system) while other methods (Inertial sensor, Image analysis system) have been introduced recently. Methods to evaluate dynamic knee laxity through the pivot shift test are already potent. However, further refinement is warranted. In addition, to correctly quantify the pivot shift test, the involved forces need to be controlled through either standardization or mechanization of the pivot shift test.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Nyckelord
- Anterior cruciate ligament
- ACL
- Injury
- Pivot shift test
- Dynamic laxity
- Instrumented laxity
- anterior cruciate ligament
- electromagnetic measurement system
- navigated acl reconstruction
- deficient knee
- single-bundle
- intraoperative evaluation
- quantitative-evaluation
- inertial sensors
- joint laxity
- kinematics
- Orthopedics
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas