Sökning: WFRF:(Turner S. F.) > (1991-1994) > ORGANIC-PHASE ENZYM...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02483naa a2200289 4500 | |
001 | oai:DiVA.org:liu-65299 | |
003 | SwePub | |
008 | 110204s1992 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-652992 URI |
040 | a (SwePub)liu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a SCHUBERT, Fu CTR INST MOLEC BIOL,W-1115 BERLIN,GERMANY; CRANFIELD INST TECHNOL,CTR BIOTECHNOL,CRANFIELD MK43 0AL,BEDS,ENGLAND;4 aut |
245 | 1 0 | a ORGANIC-PHASE ENZYME ELECTRODES FOR THE DETERMINATION OF HYDROGEN-PEROXIDE AND PHENOL |
264 | 1 | b Elsevier Science B.V., Amsterdam.c 1992 |
338 | a print2 rdacarrier | |
520 | a An amperometric horseradish peroxidase electrode is described for the determination of hydrogen peroxide in organic solvents. The enzyme was co-adsorbed with an electron mediator, hexacyanoferrate(II), to the surface of a graphite foil electrode making reagentless measurement possible. The electrochemical reduction of the enzymatically oxidized mediator was utilized as the analytical signal. The electrode can be operated in dioxane, chloroform and chlorobenzene, the presence of a small quantity of aqueous buffer being essential for activity. On this basis a small, probe-type sensor has been assembled the response of which is linearly related to hydrogen peroxide concentration between 0.05 and 1 mM. A tyrosinase sensor has been constructed by combining a Clark-type oxygen electrode with a membrane bearing adsorbed enzyme. The sensor is capable of measuring between 0.1 and 5 mM phenol in chloroform saturated with aqueous buffer. | |
653 | a TECHNOLOGY | |
653 | a TEKNIKVETENSKAP | |
700 | 1 | a SAINI, Su CTR INST MOLEC BIOL,W-1115 BERLIN,GERMANY; CRANFIELD INST TECHNOL,CTR BIOTECHNOL,CRANFIELD MK43 0AL,BEDS,ENGLAND;4 aut |
700 | 1 | a TURNER, APFu Cranfield University, UK4 aut0 (Swepub:liu)anttu13 |
700 | 1 | a SCHELLER, Fu CTR INST MOLEC BIOL,W-1115 BERLIN,GERMANY; CRANFIELD INST TECHNOL,CTR BIOTECHNOL,CRANFIELD MK43 0AL,BEDS,ENGLAND;4 aut |
710 | 2 | a CTR INST MOLEC BIOL,W-1115 BERLIN,GERMANY; CRANFIELD INST TECHNOL,CTR BIOTECHNOL,CRANFIELD MK43 0AL,BEDS,ENGLAND;b Cranfield University, UK4 org |
773 | 0 | t Sensors and actuators. B, Chemicald : Elsevier Science B.V., Amsterdam.g 7:03-jan, s. 408-411q 7:03-jan<408-411x 0925-4005x 1873-3077 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-65299 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy