SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Veraart Jelle)
 

Sökning: WFRF:(Veraart Jelle) > Assessment of preci...

Assessment of precision and accuracy of brain white matter microstructure using combined diffusion MRI and relaxometry

Coelho, Santiago (författare)
NYU Grossman School of Medicine
Liao, Ying (författare)
NYU Grossman School of Medicine
Szczepankiewicz, Filip (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,MR Physics,Forskargrupper vid Lunds universitet,Multidimensional microstructure imaging,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
visa fler...
Veraart, Jelle (författare)
NYU Grossman School of Medicine
Chung, Sohae (författare)
NYU Grossman School of Medicine
Lui, Yvonne W. (författare)
NYU Grossman School of Medicine
Novikov, Dmitry S. (författare)
NYU Grossman School of Medicine
Fieremans, Els (författare)
NYU Grossman School of Medicine
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Human Brain Mapping. - 1065-9471. ; 45:9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Joint modeling of diffusion and relaxation has seen growing interest due to its potential to provide complementary information about tissue microstructure. For brain white matter (WM), we designed an optimal diffusion-relaxometry MRI protocol that samples multiple b-values, B-tensor shapes, and echo times (TE). This variable-TE protocol (27 min) has as subsets a fixed-TE protocol (15 min) and a two-shell dMRI protocol (7 min), both characterizing diffusion only. We assessed the sensitivity, specificity, and reproducibility of these protocols with synthetic experiments and in six healthy volunteers. Compared with the fixed-TE protocol, the variable-TE protocol enables estimation of the free water fraction while also capturing compartmental (Formula presented.) relaxation times. Jointly measuring diffusion and relaxation offers increased sensitivity and specificity to microstructure parameters in brain WM with voxelwise coefficients of variation below 10%.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

biophysical modeling
brain white matter
diffusion-relaxometry
microstructure imaging
multidimensional diffusion MRI
protocol optimization

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy