2451 0a Can scatter correction software replace a grid in DR pelvic examinations?
264 c 2019-05-21
264 1b Oxford University Press (OUP),c 2019
300 a 9 s.
520 a The purpose was to examine if scatter correction software could replace a grid while maintaining image quality and reducing radiation dose for pelvic DR examinations. Grid images was produced with 70 kV and 16mAs. Anthropomorphic- and Contrast Detail RADiography (CDRAD) non-grid images were produced with 60 kV, 80 kV and 90 kV combined with five different mAs and scatter correction software. The anthropomorphic images were analyzed by absolute Visual Grading Analysis (VGA). The CDRAD images were analyzed using the CDRAD analysis software. The results showed a total of 54.6% non-grid images were evaluated as unsuitable for diagnostic use by the VGA. The CDRAD grid images showed that the IQF_inv values were significantly different (p = 0.0001) when compared to every group of non-grid images. Hereby, the conclusion stated that the scatter correction software did not compensate for the loss in image quality due to scattered radiation at the exposure levels included in a pelvic examination.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a Digital radiography
653 a image quality
653 a pelvic
653 a Radiation dose
653 a Scatter correction software
700a Mørup, Svea Deppeu University College Lillebaelt4 aut
700a Tingberg, Andersu Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine4 aut0 (Swepub:lu)rfa-ati
700a Outzen, Claus Bjørnu University College Lillebaelt4 aut
700a Kusk, Kirsten Weberu Hospital of South West Jutland, Esbjerg4 aut
700a Nielsen, Rita Mølleru Hospital of South West Jutland, Esbjerg4 aut
700a Midtgård, Marieu Lillebaelt Hospital4 aut
700a Winther, Martin Brændegaardu Slagelse Hospital4 aut
700a Waaler, Dagu Norwegian University of Science and Technology4 aut
700a Kusk, Martin Weberu Hospital of South West Jutland, Esbjerg4 aut
710a University College Lillebaeltb Medicinsk strålningsfysik, Lund4 org
773t Radiation Protection Dosimetryd : Oxford University Press (OUP)g 187:1, s. 8-16q 187:1<8-16x 1742-3406x 0144-8420
856u http://dx.doi.org/10.1093/rpd/ncz129y FULLTEXT
8564 8u https://lup.lub.lu.se/record/79db9705-dbbc-4bd6-b839-1ed1349eedba
8564 8u https://doi.org/10.1093/rpd/ncz129

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy