Sökning: WFRF:(Just Justus) >
In Situ Monitoring ...
In Situ Monitoring of Cu2ZnSnS4 Absorber Formation With Raman Spectroscopy During Mo/Cu2SnS3/ZnS Thin-Film Stack Annealing
-
- van Duren, Stephan (författare)
- Helmholtz Zentrum Berlin, Dept Struct & Dynam Energy Mat, D-14109 Berlin, Germany.
-
- Ren, Yi (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
- Scragg, Jonathan, 1983- (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
visa fler...
-
- Just, Justus (författare)
- Helmholtz Zentrum Berlin, Dept Struct & Dynam Energy Mat, D-14109 Berlin, Germany.
-
- Unold, Thomas (författare)
- Helmholtz Zentrum Berlin, Dept Struct & Dynam Energy Mat, D-14109 Berlin, Germany.
-
visa färre...
-
Helmholtz Zentrum Berlin, Dept Struct & Dynam Energy Mat, D-14109 Berlin, Germany Fasta tillståndets elektronik (creator_code:org_t)
- IEEE, 2017
- 2017
- Engelska.
-
Ingår i: IEEE Journal of Photovoltaics. - : IEEE. - 2156-3381 .- 2156-3403. ; 7:3, s. 906-912
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In recent years, Cu-2 ZnSn(S,Se)(4) (kesterite) has become increasingly popular as a sustainable alternative absorber material. Many processes for kesterite synthesis involve a high temperature annealing step (>450 degrees C). This study investigates the possibility of Raman spectroscopy as an in situ monitoring technique during high temperature annealing up to 550 degrees C. Temperature-dependent behavior of Cu2SnS3 (CTS) and Cu2ZnSnS4 (CZTS) was studied for reference purposes. The synthesis of CZTS was performed by annealing a stacked Mo/CTS/ZnS precursor on a glass substrate. Annealing of the precursor stack resulted in formation of kesterite and could be monitored in situ by its main A-mode at 338 cm(-1). At higher temperatures, this mode shifts to lower wavenumbers, is broadened and reduced in intensity. This can be attributed to combined effects of thermal expansion and anharmonic phonon coupling. The shift of the peak position is linearly proportional to the temperature. Thus, given proper calibration, fitting the peak position of the 338 cm(-1) mode during the process yields the sample temperature. Implementation of in situ monitoring with Raman spectroscopy would be a step forward toward desired process control and monitoring during this crucial high temperature annealing step in kesterite synthesis.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Nyckelord
- In situ monitoring
- kesterite
- process control
- Raman scattering
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek