SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0099 2399 OR L773:1878 3554
 

Sökning: L773:0099 2399 OR L773:1878 3554 > (2010-2014) > Does a combination ...

Does a combination of two radiographs increase accuracy in detecting acid-induced periapical lesions and does it approach the accuracy of cone-beam computed tomography scanning?

Soǧur, Elif (författare)
Gröndahl, Hans-Göran, 1940 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Baks, B. Güniz (författare)
visa fler...
Mert, Ali (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2012
2012
Engelska.
Ingår i: Journal of Endodontics. - : Elsevier BV. - 0099-2399. ; 38, s. 131-136
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: The purpose of this study was to determine whether the use of a combination of 2 images (storage phosphor plates [SPPs] and F-speed films [Eastman Kodak, Rochester, NY]) with a 10° difference in horizontal beam angulation resulted in better detectability of chemically created periapical defects than when only 1 image was used and whether a detectability as good as that achieved by limited cone-beam computed tomography (LCBCT) scanning could be achieved. Methods: Lesions were created by 1, 1.5, and 2 hours of acid application apical to extracted teeth in jaw specimens. After repositioning, teeth were radiographed with Accu-I-Tomo LCBCT, Digora Optime SPP system, and F-speed films. The SPPs and films were exposed at 0° and 10° horizontal angulations. The diagnostic accuracy (Az) was compared using 2-way analysis of variance; pair-wise comparisons were performed using the post hoc t test. Kappa was used to measure interobserver agreement. Results: A combination of 2 exposures with a 10° difference in horizontal angulation caused an increase, although not statistically significant, in the accuracy of both films and SPPs for all acid durations (P >.05) compared with when only 1 exposure was used. The accuracy did not approach that of LCBCT. Conclusions: Using a combination of 2 exposures instead of 1 did not significantly increase the accuracy in detecting acid-induced lesions at the apices of single-rooted premolars. The accuracy of LCBCT was superior. Copyright © 2012 American Association of Endodontists.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Diagnosis
digital volumetric tomography
endodontics
horizontal angulation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Soǧur, Elif
Gröndahl, Hans-G ...
Baks, B. Güniz
Mert, Ali
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Journal of Endod ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy