Improved reliability of ultrasonic surveillance of abdominal aortic aneurysms
-
Länne, T (författare)
-
Sandgren, T (författare)
-
- Mangell, Peter (författare)
- Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups
-
visa fler...
-
- Sonesson, Björn (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
Hansen, F (författare)
-
visa färre...
-
(creator_code:org_t)
- 1997
- 1997
- Engelska.
-
Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:2, s. 149-153
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVES: Small abdominal aortic aneurysms (AAA) are usually managed conservatively by serial ultrasound examinations to assess size. The development of the size of the AAA will determine whether the patient is a candidate for surgery. The precision of measurement is therefore of considerable importance. The aim of this study was to evaluate the accuracy and the reproducibility of a newly developed echo-tracking ultrasonic system in the size evaluation of AAA. DESIGN: Prospective study at a University Hospital. MATERIAL AND METHODS: An echo-tracking ultrasound system with a 3.5 MHz transducer was used in 54 patients with AAA. Thirty-six patients had repeated measurements by one technician to evaluate the intra-observer variability. In another 18 patients with aortic dilatation/AAA, the measurements were repeated by a second technician in a blinded fashion with calculation of inter-observer variability. The reproducibility was evaluated both using linear regression and plots according to the method described by Bland and Altman. RESULTS: The mean diameter of the aorta was 37 mm (range 21-51 mm). The coefficient of correlation of repetitive measurements with one observer was r = 0.99 and with two observers r = 0.99. The intra-observer variability was 0.78 mm (S.D.) and the inter-observer variability 0.93 mm (S.D.). The intra- and inter-observer coefficient of variation (CV) was 2-3%. CONCLUSIONS: The newly developed echo-tracking ultrasonography seems at present to be the most accurate and reliable method to follow the diameter of an abdominal aortic aneurysm detecting relevant changes in the diameter exceeding 2 mm (2 S.D.). Thus it fulfils the requirements both for follow-up of conservatively managed AAAs and endovascularly treated aneurysms.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Nyckelord
- Ultrasonography
- Echo-tracking
- Abdominal aortic aneurysm
- Aneurysm surveillance