Sökning: WFRF:(Sathre Roger 1964 ) >
Lifecycle primary e...
Lifecycle primary energy analysis of low-energy timber building systems for multi-story residential buildings
-
- Dodoo, Ambrose, 1979- (författare)
- Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET),SBER
-
- Gustavsson, Leif, 1954- (författare)
- Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET),SBER
-
- Sathre, Roger, 1964- (författare)
- Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET),SBER
-
(creator_code:org_t)
- Elsevier BV, 2014
- 2014
- Engelska.
-
Ingår i: Energy and Buildings. - : Elsevier BV. - 0378-7788 .- 1872-6178. ; 81, s. 84-97
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A system-wide lifecycle approach is used here to explore the primary energy implications of three timber building systems for a multi-storey building designed to a high energy-efficiency level. The three building systems are: cross laminated timber, beam -and-column, and modular prefabricated systems. The analysis considers the energy and material flows in the production, use and post-use lifecycle stages of the buildings. The effects of insulation material options and the contribution of different building elements to the production energy for the buildings are explored. The results show that external and internal walls account for the biggest share of the production energy for all building systems and its contribution is comparable for the different systems. In contrast, there is significant variation in the production primary energy for the roof-ceilings and intermediate floor-ceilings for the different building systems. Overall, the cross laminated timber building system gives the lowest lifecycle primary energy balance, as this building is insulated with stone wool and has better airtightness in contrast to the other building systems which are insulated with glass wool and have lower airtightness performance. With improved airtightness and insulation substitution, the total primary energy use for the beam-and-column and modular building systems can be reduced by 7% and 9%, respectively.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering (hsv//eng)
Nyckelord
- Bioenergiteknik/Energi- och Miljöteknik
- Bioenergy Technology
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas