100a Sandborg, Michaelu Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)micsa02
2451 0a Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages
264 c 2006-10-18
264 1b Wiley,c 2006
520 a The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography.
650 7a NATURVETENSKAPx Biologix Biofysik0 (SwePub)106032 hsv//swe
650 7a NATURAL SCIENCESx Biological Sciencesx Biophysics0 (SwePub)106032 hsv//eng
653 a chest radiography
653 a signal-to-noise ratio
653 a visual grading analysis
653 a tube voltage
653 a image quality
653 a effective dose
653 a pelvis radiography
653 a computed
653 a radiography
653 a diagnostic radiography
653 a MEDICINE
700a Tingberg, Andersu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Department of Radiation Physics, Malmö University Hospital, Malmö, Sweden4 aut0 (Swepub:lu)rfa-ati
700a Ullman, Gustafu Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)gusul07
700a Dance, David R.u Joint Department of Physics, The Royal Marsden NHS Trust and Institute of Cancer Research, London4 aut
700a Alm Carlsson, Gudrunu Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)gudal03
710a Linköpings universitetb Medicinsk radiofysik4 org
773t Medical Physicsd : Wileyg 33:11, s. 4169-4175q 33:11<4169-4175x 0094-2405
856u http://dx.doi.org/10.1118/1.2362871y FULLTEXT
856u http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-11662y Link to Ph.D. thesis
8564 8u https://lup.lub.lu.se/record/685772
8564 8u https://doi.org/10.1118/1.2362871
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-13220

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view