SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kaczmarski Krzysztof)
 

Sökning: WFRF:(Kaczmarski Krzysztof) > Strategies for pred...

Strategies for predictive modeling of overloaded oligonucleotide elution profiles in ion-pair chromatography

Lesko, Marek (författare)
Karlstads universitet,Institutionen för ingenjörs- och kemivetenskaper (from 2013)
Kaczmarski, Krzysztof (författare)
Rzeszów University of Technology, Poland
Jora, Manasses (författare)
AstraZeneca, Sweden
visa fler...
Stavenhagen, Kathrin (författare)
AstraZeneca, Sweden
Leek, Tomas (författare)
AstraZeneca, Sweden
Czechtizky, Werngard (författare)
AstraZeneca, Sweden
Fornstedt, Torgny, 1957- (författare)
Karlstads universitet,Institutionen för ingenjörs- och kemivetenskaper (from 2013)
Samuelsson, Jörgen, 1971- (författare)
Karlstads universitet,Institutionen för ingenjörs- och kemivetenskaper (from 2013)
visa färre...
 (creator_code:org_t)
Elsevier, 2023
2023
Engelska.
Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1711
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Due to their potential for gene regulation, oligonucleotides have moved into focus as one of the preferred modalities modulating currently undruggable disease-associated targets. In the course of synthesis and storage of oligonucleotides a significant number of compound-related impurities can be generated. Purification protocols and analytical methods have become crucial for the therapeutic application of any oligonucleotides, be they antisense oligonucleotides (ASOs), small interfering ribonucleic acids (siRNAs) or conjugates. Ion-pair chromatography is currently the standard method for separating and analyzing therapeutic oligonucleotides. Although mathematical modeling can improve the accuracy and efficiency of ion-pair chromatography, its application remains challenging. Simple models may not be suitable to treat advanced single molecules, while complex models are still inefficient for industrial oligonucleotide optimization processes. Therefore, fundamental research to improve the accuracy and simplicity of mathematical models in ion-pair chromatography is still a necessity. In this study, we predict overloaded concentration profiles of oligonucleotides in ion-pair chromatography and compare relatively simple and more advanced predictive models. The experimental system consists of a traditional C18 column using (dibutyl)amine as the ion-pair reagent and acetonitrile as organic modifier. The models were built and tested based on three crude 16-mer oligonucleotides with varying degrees of phosphorothioation, as well as their respective n – 1 and (P = O)1 impurities. In short, the proposed models were suitable to predict the overloaded concentration profiles for different slopes of the organic modifier gradient and column load. 

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Adsorption modeling
Inverse method
Ion-pair chromatography
Oligonucleotides
Overloaded profiles
Kemi
Chemistry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy