SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Leonardsson Olof)
 

Sökning: WFRF:(Leonardsson Olof) > Monoblock hemiarthr...

Monoblock hemiarthroplasties for femoral neck fractures - A part of orthopaedic history? Analysis of national registration of hemiarthroplasties 2005-2009.

Rogmark, Cecilia (författare)
Lund University,Lunds universitet,Ortopedi - klinisk och molekylär osteoporosforskning,Forskargrupper vid Lunds universitet,Orthopedics - Clinical and Molecular Osteoporosis Research,Lund University Research Groups
Leonardsson, Olof (författare)
Lund University,Lunds universitet,Ortopedi - klinisk och molekylär osteoporosforskning,Forskargrupper vid Lunds universitet,Orthopedics - Clinical and Molecular Osteoporosis Research,Lund University Research Groups
Garellick, Göran (författare)
visa fler...
Kärrholm, Johan (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2012
2012
Engelska.
Ingår i: Injury. - : Elsevier BV. - 1879-0267 .- 0020-1383. ; 43:6, s. 946-949
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study from the Swedish Hip Arthroplasty Register (SHAR) compares cemented (Thompson(®), Exeter Trauma Stem (ETS)(®)) and uncemented (Austin-Moore(®)) monoblock hemiarthroplasties (n=1116 and 616, respectively) with modular ones (n=18,659). Austin-Moore(®) prostheses lead to more re-operations (6.7%) compared to modular implants (3.5%) and Thompson(®)/ETS(®) (2.4%). A Cox regression analysis, adjusting for other risk factors, shows twice the risk of re-operation for Austin-Moore(®) implants (CI 1.5-2.8), in particular, due to periprosthetic fracture (5.4; CI 3.2-9.1) and dislocation (1.9; CI 1.3-3.0). The Thompson(®)/ETS(®) implants do not influence the overall risk of re-operation (0.7; CI 0.5-1.2) compared to modular implants and decrease the risk of re-operation due to infection (0.2;CI 0.04-0.7). An increased risk of re-operation is also seen in men, age groups 75-85 years and <75 years and after secondary fracture surgery. Both Swedish and Australian orthopaedic surgeons have decreased their use of Austin-Moore(®) implants after reports from their national arthroplasty registers identifying inferior outcome for this implant. Due to the increased risk of re-operations, it should not be used in modern orthopaedic care. Cemented Thompson(®) or ETS(®) implants could still be suitable for the oldest, low-activity patients. To finally decide if there is a place for them, patient-reported outcome must be analysed as well.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Injury (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rogmark, Cecilia
Leonardsson, Olo ...
Garellick, Göran
Kärrholm, Johan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Injury
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy