Multicenter Consistency Assessment of Valvular Flow Quantification With Automated Valve Tracking in 4D Flow CMR

Juffermans, Joe F. (författare)
Leiden University Medical Centre
Minderhoud, Savine C.S. (författare)
Erasmus University Medical Center
Wittgren, Johan (författare)
Skåne University Hospital,Lund University
visa fler...
Kilburg, Anton (författare)
Johannes-Gutenberg University Mainz,Universitätsmedizin Mainz
Ese, Amir (författare)
Johannes-Gutenberg University Mainz,Universitätsmedizin Mainz
Fidock, Benjamin (författare)
University of Sheffield
Zheng, Yu Cong (författare)
Fu Wai Hospital
Zhang, Jun Mei (författare)
National University of Singapore
Blanken, Carmen P.S. (författare)
Academic Medical Center of University of Amsterdam (AMC)
Lamb, Hildo J. (författare)
Leiden University Medical Centre
Goeman, Jelle J. (författare)
Leiden University Medical Centre
Carlsson, Marcus (författare)
Lund University,Lunds universitet,Hjärt-MR-gruppen i Lund,Forskargrupper vid Lunds universitet,Lund Cardiac MR Group,Lund University Research Groups,Skåne University Hospital
Zhao, Shihua (författare)
Fu Wai Hospital
Planken, R. Nils (författare)
Academic Medical Center of University of Amsterdam (AMC)
van Ooij, Pim (författare)
Academic Medical Center of University of Amsterdam (AMC)
Zhong, Liang (författare)
National University of Singapore
Chen, Xiuyu (författare)
Fu Wai Hospital
Garg, Pankaj (författare)
University of Sheffield
Emrich, Tilman (författare)
Johannes-Gutenberg University Mainz,Universitätsmedizin Mainz,German Centre for Cardiovascular Research
Hirsch, Alexander (författare)
Erasmus University Medical Center
Töger, Johannes (författare)
Lund University,Lunds universitet,Hjärt-MR-gruppen i Lund,Forskargrupper vid Lunds universitet,Lund Cardiac MR Group,Lund University Research Groups,Skåne University Hospital
Westenberg, Jos J.M. (författare)
Leiden University Medical Centre
visa färre...
 (creator_code:org_t)
Elsevier BV, 2021
2021
Engelska 13 s.
Ingår i: JACC: Cardiovascular Imaging. - : Elsevier BV. - 1936-878X. ; 14:7, s. 1354-1366
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: This study determined: 1) the interobserver agreement; 2) valvular flow variation; and 3) which variables independently predicted the variation of valvular flow quantification from 4-dimensional (4D) flow cardiac magnetic resonance (CMR) with automated retrospective valve tracking at multiple sites. Background: Automated retrospective valve tracking in 4D flow CMR allows consistent assessment of valvular flow through all intracardiac valves. However, due to the variance of CMR scanners and protocols, it remains uncertain if the published consistency holds for other clinical centers. Methods: Seven sites each retrospectively or prospectively selected 20 subjects who underwent whole heart 4D flow CMR (64 patients and 76 healthy volunteers; aged 32 years [range 24 to 48 years], 47% men, from 2014 to 2020), which was acquired with locally used CMR scanners (scanners from 3 vendors; 2 1.5-T and 5 3-T scanners) and protocols. Automated retrospective valve tracking was locally performed at each site to quantify the valvular flow and repeated by 1 central site. Interobserver agreement was evaluated with intraclass correlation coefficients (ICCs). Net forward volume (NFV) consistency among the valves was evaluated by calculating the intervalvular variation. Multiple regression analysis was performed to assess the predicting effect of local CMR scanners and protocols on the intervalvular inconsistency. Results: The interobserver analysis demonstrated strong-to-excellent agreement for NFV (ICC: 0.85 to 0.96) and moderate-to-excellent agreement for regurgitation fraction (ICC: 0.53 to 0.97) for all sites and valves. In addition, all observers established a low intervalvular variation (≤10.5%) in their analysis. The availability of 2 cine images per valve for valve tracking compared with 1 cine image predicted a decreasing variation in NFV among the 4 valves (beta = −1.3; p = 0.01). Conclusions: Independently of locally used CMR scanners and protocols, valvular flow quantification can be performed consistently with automated retrospective valve tracking in 4D flow CMR.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

automated retrospective valve tracking
valvular flow assessment regurgitation
whole heart 4D flow CMR

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy