Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs
-
- Mangell, Peter (författare)
- Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups
-
- Malina, Martin (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
Vogt, K (författare)
-
visa fler...
-
- Lindh, Mats (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
-
Schroeder, T (författare)
-
Risberg, B (författare)
-
Brunkwall, J (författare)
-
Länne, T (författare)
-
visa färre...
-
(creator_code:org_t)
- 1996
- 1996
- Engelska.
-
Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 12:3, s. 287-294
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVE: To study the stent/vessel interaction and distensibility following the natural increase in vascular diameter using self-expanding and balloon-expanded stents. DESIGN: Open experimental study. SETTING: Animal laboratory, university hospital. MATERIALS AND METHODS: Eight Palmaz (P) and eight Gianturco (G) stents were transluminally placed in the infrarenal aortas of 16 pigs. Pulsatile diameter changes above, at and below the stents were non-invasively monitored with an ultrasound phase-locked echo-tracking system before and immediately after stenting and at 4 and 18 weeks. Blood pressure was registered intra-arterially and stiffness (beta) was calculated. Intravascular ultrasound (IVUS) was performed at 18 weeks. RESULTS: Median weight increased from 20 kg (19-26) to 93 kg (62-130). Diameter of the aorta increased 60%. In group P no pulsatile diameter change could be measured at the stent (beta = infinity). In group G stenting increased stiffness from beta 20.7 (9.2) to 43.2 (8.0) (p < 0.05). After 18 weeks stiffness returned to beta 20.1 (12.4). Expanded, median diameter of the P stents was 7.4 (0.8) mm, not increasing after 18 weeks. Initial diameter of the G stents was 7.8 (1.0) mm, increasing 56% to 12.2 (2.3) mm (p < 0.05). IVUS revealed the G stents to be well attached to the vascular wall, but five P stents were detached within half of the circumference. CONCLUSION: Self-expanding stents follow the pulsatile diameter change of the vessel wall, not adversely affecting distensibility after 18 weeks. They show good attachment despite 56% dilation. In contrast, the balloon-expanded stents do not show pulsatile movement and may detach during vessel diameter increase. This may be of importance when choosing stents for endovascular treatment of abdominal aortic aneurysms.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Nyckelord
- Endovascular stents
- Aorta
- Ultrasound
- Diameter
- Distensibility